Graphite epoxy composite electrodes modified with bacterial cells
(Elsevier Science Sa, 2006)
The modification of a graphite-epoxy composite electrode (GECE) with bacterial cells along with an analytical application are presented. Pseudomonas putida DSM 50026 was used as a biological component and the measurement ...
alpha-glucosidase based bismuth film electrode for inhibitor detection
(Elsevier, 2007)
A biosensing system based on (alpha-glucosidase (AG) activity was developed by using bismuth film modified glassy carbon electrode (BiFE). AG enzyme was immobilized on the BiFE by means of gelatin membrane and the activity ...
Effects of mediators on the laccase biosensor response in paracetamol detection
(Wiley, 2006)
An enzyme electrode suitable for paracetamol detection was developed by immobilizing laccase on a dissolved-oxygen probe surface. The immobilization procedure was achieved by means of gelatin, which was then cross-linked ...
Carbon nanotube composite as novel platform for microbial biosensor
(Wiley-V C H Verlag Gmbh, 2007)
The presented work includes the development of a microbial biosensor based on a carbon-nanotube epoxy composite (CNTEC) platform used as supporting electrode for cell immobilization. For this purpose, cells of Pseudomonas ...
Development of a microbial biosensor based on carbon nanotube (CNT) modified electrodes
(Elsevier Science Inc, 2007)
Pseudomonas putida DSM 50026 cells were used as the biological component and the measurement was based on the respiratory activity of the cells estimated from electrochemical measurements. The cells were immobilised on ...
Examination of performance of glassy carbon paste electrode modified with gold nanoparticle and xanthine oxidase for xanthine and hypoxanthine detection
(Elsevier, 2007)
A composite electrode was prepared by modifying glassy carbon microparticles with gold nanoparticles (Au-nps) and xanthine oxidase enzyme (XOD) for xanthine (X) and hypoxanthine (Hx) detection. After the optimization of ...
A biosensor based on graphite epoxy composite electrode for aspartame and ethanol detection
(Elsevier Science Bv, 2006)
A gelatin membrane with carboxyl esterase and alcohol oxidase was subsequently integrated onto the surface of a graphite epoxy composite electrode (GECE). The developed biosensors showed linearity in the range of 2.5-400 ...
The usage of a bismuth film electrode as transducer in glucose biosensing
(Springer Wien, 2008)