Effect of metal sensitizers on photochemical vapor generation of bismuth for analytical atomic spectrometry
(Charles Univ, Fac Science, 2019)
Conditions of photochemical vapor generation of bismuth were optimized in a flow-injection system with a standard mercury low-pressure tube lamp and a coiled reactor. A high-resolution continuum source atomic absorption ...
Determination of Selenium by Platinum-coated Tungsten Coil Trap Hydride Generation-Atomic Absorption Spectrometry
(ATOMIC SPECTROSCOPY PRESS LTD, 2021)
A highly sensitive analytical technique was developed in which gaseous hydrogen selenide generated by sodium tetrahydroborate reduction was transported and trapped on a resistively heated platinum-coated W-coil trap for ...