Anatomical and functional changes after aortic valve replacement with different sizes of mechanical valves

Thumbnail

View/Open

Tam metin / Full text (93.52Kb)

Date

2018

Author

İlhan, Gökhan
Bozok, Şahin
Özpak, Berkan
Kara, Hakan
Yazman, Serkan
Bayrak, Serdar
Gürbüz, Ali

Metadata

Show full item record

Abstract

Objective: To date. there is no consensus on the selection of type and size of prosthetic valve for aortic valve replacement (AVR). The aim of this study was to compare anatomical and functional changes occurring in the left ventricle after AVR with different sizes of mechanical valves. Methods: A total of 92 patients with serious aortic valve stenosis. who underwent AVR between March 2001 and June 2008 using mechanical valves of different sizes. were retrospectively analysed. The sizes of mechanical valves v ere 19, 21, 23 and 25 mm. All patients were assessed pre-operatively and at six months and in first, third and fifth years postoperatively. The left ventricle was assessed with electrocardiography, echocardiography and telecardiography and compared in the four patient groups, constituted according to the mechanical valve size used. Results: In all groups, left ventricular mass and mass index. transvalvular aortic gradient. thicknesses of the interventricular septum and posterior wall and left ventricular end-systolic and end-diastolic diameters had decreased significantly post surgery. Left ventricular ejection fraction and exercise capacity had increased significantly (p < 0.001). The most noteworthy anatomical and functional improvements were seen in patients who had received 23- and 25-mm mechanical valves. Conclusion: Mechanical valve e replacement should not be performed with small size Ayes because of the higher residual gradient.

Source

Cardiovascular Journal of Africa

Volume

29

Issue

6

URI

https://doi.org/10.5830/CVJA-2018-037
https://hdl.handle.net/20.500.12809/1301

Collections

  • Cerrahi Tıp Bilimleri Bölümü Koleksiyonu [543]
  • PubMed İndeksli Yayınlar Koleksiyonu [2082]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Muğla

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Guide|| Instruction || Library || Muğla Sıtkı Koçman University || OAI-PMH ||

Muğla Sıtkı Koçman University, Muğla, Turkey
If you find any errors in content, please contact:

Creative Commons License
Muğla Sıtkı Koçman University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.