Investigation of indoor air quality and thermal comfort condition in airport terminal buildings

Thumbnail

View/Open

Tam metin / Full text (364.2Kb)

Date

2020

Author

Akyüz, Mehmet Kadri
Kafalı, Haşim
Altuntaş, Önder

Metadata

Show full item record

Abstract

Purpose This paper aims to measure the thermal comfort conditions and indoor air quality parameters, through on-site measurements taken in the areas mostly occupied by the passengers and airport staff. Terminal buildings consist of areas with various functions. Heating, ventilation and air conditioning requirements vary from area to area, thus leading to challenges in the management of indoor environment quality. Therefore, the study focuses on investigating the indoor environment conditions in various areas of the terminal buildings. Design/methodology/approach In this study, the thermal comfort and indoor air quality were evaluated based on the parameters [CO(2)concentration, relative humidity, temperature, predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD)] collected for summer 2019 from different zones inside the International Dalaman Airport terminal building located in the southwest of Turkey. The measurements were performed in the areas mostly occupied by the airport staff and passengers (check-in area, security control areas, international departure lounge, domestic departure lounge and baggage claim hall). Findings As a result of the study, it was observed that the CO(2)concentration was 480-965 ppm, the relative humidity was 51.9-75.8% and the temperature was in the range of 23.9 degrees C-28.3 degrees C inside the airport terminal. The PMV values were determined to be in the range of -0.23 to 0.67, and the PPD values 5-15%, which are used to measure the thermal comfort conditions. Originality/value There has been limited study on the determination of the indoor air quality in airport terminals and the investigation of the thermal comfort conditions. However, in this study, indoor air quality and thermal comfort conditions were determined by on-site measurements in the five mostly occupied areas by passengers and employees in the terminal building.

Source

Aircraft Engineering and Aerospace Technology

URI

https://doi.org/10.1108/AEAT-06-2020-0118
https://hdl.handle.net/20.500.12809/321

Collections

  • Havacılık Yönetimi Bölümü Koleksiyonu [9]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Muğla

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Guide|| Instruction || Library || Muğla Sıtkı Koçman University || OAI-PMH ||

Muğla Sıtkı Koçman University, Muğla, Turkey
If you find any errors in content, please contact:

Creative Commons License
Muğla Sıtkı Koçman University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.