Basit öğe kaydını göster

dc.contributor.authorKula, I.
dc.contributor.authorArslan, Y.
dc.contributor.authorBakirdere, S.
dc.contributor.authorAtaman, O. Y.
dc.date.accessioned2020-11-20T16:36:14Z
dc.date.available2020-11-20T16:36:14Z
dc.date.issued2008
dc.identifier.issn0584-8547
dc.identifier.urihttps://doi.org/10.1016/j.sab.2008.03.020
dc.identifier.urihttps://hdl.handle.net/20.500.12809/4936
dc.description35th Biennial Colloquium Spectroscopicum Internationale - SEP 23-27, 2007 - Xiamen, PEOPLES R CHINAen_US
dc.descriptionWOS: 000258815800006en_US
dc.description.abstractA novel analytical technique was developed where gaseous hydrogen selenide formed by sodium tetra hydrobora te reduction is transported to and trapped on a resistively heated gold-coated W-coil atom trap for in situ preconcentration. Gold coating on W-coil was prepared by using an organic solution of Au. The atom trap is held at 165 degrees C during the collection stage and is heated up to 675 degrees C for revolatilization; analyte species formed are transported to an externally heated quartz T-tube where the atornization takes place and the transient signal is obtained. The carrier gas consisted of 112.5 ml min' At with 75 ml min(-1) H-2 during the collection step and 112.5 ml min(-1) At with 450 ml min(-1) H-2 in the revolatilization step. The half width of the transient signal obtained is less than 0.5 s. The RSD for the measurements was found to be 3.9% (n = 11) for 0.10 mu g l(-1) Se using peak height measurements. The calibration plot for 27.0 ml of sample collected in 4.0 min using a flow rate of 6.75 ml min(-1) was linear between 0.13 and 2.0 mu g l(-1) of Se. The limit of detection (3 s) is 39 ng l(-1). The enhancement factor for the characteristic concentration (Co) was found to be 20.1 when compared to conventional hydride generation atomic absorption spectrometry system without trap. In order to check the accuracy of the method. standard reference material, natural water NIST 1640 was employed; the result was found to be in good agreement with the certified value at the 95% confidence level. (c) 2008 Elsevier B.V. All rights reserved.en_US
dc.description.sponsorshipChinese Chem Soc, Chinese Phys Soc, Chinese Spectroscopy Soc, Natl Nat Sci Fdn China, Xiamen Municipal Govt, Xiamen Univen_US
dc.item-language.isoengen_US
dc.publisherPergamon-Elsevier Science Ltden_US
dc.item-rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectgold-coated tungsten coil atom trapen_US
dc.subjectseleniumen_US
dc.subjectatomic absorption spectrometry. hydride generationen_US
dc.titleA novel analytical system involving hydride generation and gold-coated W-coil trapping atomic absorption spectrometry for selenium determination at ng l(-1) levelen_US
dc.item-typeconferenceObjecten_US
dc.contributor.departmenten_US
dc.contributor.departmentTemp[Kula, I.; Arslan, Y.; Bakirdere, S.; Ataman, O. Y.] Middle E Tech Univ, Dept Chem, TR-06531 Ankara, Turkey; [Kula, I.] Mugla Univ, Dept Chem, TR-48000 Mugla, Turkey; [Arslan, Y.] Ataturk Univ, Dept Chem, TR-25240 Erzurum, Turkey; [Bakirdere, S.] Zonguldak Karaelmas Univ, Dept Chem, TR-67100 Zonguldak, Turkeyen_US
dc.identifier.doi10.1016/j.sab.2008.03.020
dc.identifier.volume63en_US
dc.identifier.issue8en_US
dc.identifier.startpage856en_US
dc.identifier.endpage860en_US
dc.relation.journalSpectrochimica Acta Part B-Atomic Spectroscopyen_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster