• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace@Muğla
  • Fakülteler
  • Tıp Fakültesi
  • Cerrahi Tıp Bilimleri Bölümü Koleksiyonu
  • View Item
  •   DSpace@Muğla
  • Fakülteler
  • Tıp Fakültesi
  • Cerrahi Tıp Bilimleri Bölümü Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Refractive outcomes of table-mounted and hand-held auto-refractometers in children: an observational cross-sectional study

Thumbnail

View/Open

Tam metin / Full text (1.063Mb)

Date

2021

Author

Karabulut, Müjdat
Karabulut, Sinem
Karalezli, Aylin

Metadata

Show full item record

Citation

Karabulut M, Karabulut S, Karalezli A. Refractive outcomes of table-mounted and hand-held auto-refractometers in children: an observational cross-sectional study. BMC Ophthalmol. 2021 Dec 9;21(1):424. doi: 10.1186/s12886-021-02199-5. PMID: 34879852; PMCID: PMC8656057.

Abstract

Background: To compare the refractive results of hand-held and table-mounted autorefractors. Methods: We designed this study as an observational, cross-sectional study. We compared the mean spheric and cylinder power, spherical equivalent, Jackson cross-cylinder values, determined the limits of agreement (LoA), and evaluated the reliability of two autorefractors. Results: We evaluated 256 eyes of 256 pediatric patients (mean age, 9.12 ± 2.26 years; range, 5-16 years). 49% of the patients were female, and 51% were male. The Nidek HandyRef-K autorefractor measured relatively more astigmatism (P < 0.001) and less hyperopia (P = 0.024). The mean differences and 95% LoA were 0.06 D ± 0.47 D (- 0.82 D to 0.98 D) in spherical power, 0.08 D ± 0.28 D (- 0.47 D to 0.64 D) in cylindrical power, 0.11 D ± 0.47 D (- 0.81 D to 1.01 D) in spherical equivalent, 0.02 D ± 0.36 D (- 0.73 D to 0.69 D) in Jackson cross-cylinder power at 0°, 0.005 D ± 0.54 D (- 1.07 D to 1.06 D) in Jackson cross-cylinder power at 45°. We found the difference within 0.50 D in 244 (95%) eyes for spherical power, in 245 (96%) eyes for cylindrical power, 228 (89%) eyes for spherical equivalent, 224 (87%) eyes for Jackson cross-cylinder power at 0°, 213 (83%) eyes for Jackson cross-cylinder power at 45°. When comparing devices, there were strong correlations for spherical power (Spearman's rho = 0.99, P < 0.001), cylindrical power (Spearman's rho = 0.88, P < 0.001), and spherical equivalent (Spearman's rho = 0.98, P < 0.001). Conclusion: Two autorefractors showed clinically applicable agreement limits; excellent reliability for spherical power and spherical equivalent and good reliability for cylindrical power; high positive percent agreement for spherical and cylindrical power, spherical equivalent, Jackson cross-cylinder power at 0°and 45°. These results showed that both devices might be used interchangeably for screening of refractive error in children.

Source

BMC Ophthalmology

Volume

21

Issue

1

URI

https://doi.org/10.1186/s12886-021-02199-5
https://hdl.handle.net/20.500.12809/9707

Collections

  • Cerrahi Tıp Bilimleri Bölümü Koleksiyonu [543]
  • PubMed İndeksli Yayınlar Koleksiyonu [2082]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Muğla

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Guide|| Instruction || Library || Muğla Sıtkı Koçman University || OAI-PMH ||

Muğla Sıtkı Koçman University, Muğla, Turkey
If you find any errors in content, please contact:

Creative Commons License
Muğla Sıtkı Koçman University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.