• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Muğla
  • Fakülteler
  • Teknoloji Fakültesi
  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu
  • Öğe Göster
  •   DSpace@Muğla
  • Fakülteler
  • Teknoloji Fakültesi
  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Environmental impact assessment of a real geothermal driven power plant with two-stage ORC using enhanced exergo-environmental analysis

Thumbnail

Göster/Aç

Tam metin / Full text (1.536Mb)

Tarih

2022

Yazar

Gürbüz Yağız, Emine
Güler, Onur Vahip
Keçebaş, Ali

Üst veri

Tüm öğe kaydını göster

Künye

Gürbüz, E.Y., Güler, O.V., Keçebaş, A., 2022. Environmental impact assessment of a real geothermal driven power plant with two-stage ORC using enhanced exergo-environmental analysis. Renewable Energy 185, 1110–1123. doi:10.1016/j.renene.2021.12.097

Özet

Geothermal driven power plants (GPPs) with two-stage ORC are mostly used in low-temperature geothermal fields around the World. The environmental impacts of these GPPs create a gap in the literature. In this study, enhanced exergo-environmental analysis for the GPP and its components is conducted as a case study. With the analysis, the component-related, exergy degradation-related, and pollution formation-related environmental impacts (EIs) are separated endogenous/exogenous and avoidable/unavoidable parts. In this way, detailed information about the interaction and improvement potential between components is acquired by using the recommended performance indicators. The results of the study show that for the enhanced exergo-environmental analysis, EI related to exergy destruction of components is predominated. In the traditional exergo-environmental analysis the total amount of EI is condenser with 1.386 Pt/h while in the enhanced one the highest avoidable-endogenous exergy destruction is condenser with 716 Pt/h. The value of EI which is caused by electricity generation is 0.108 Pts/kWh. The EI value of geothermal fluid is 11.8 Pt/GJ. The EI value of the plant's avoidable endogenous pollution formation is 8 Pt/h. As the reason for this, the mass flow rate of the geothermal fluid steam and the amount of NCG gas in it are effective. Eventually, if the plant could be operated under enhanced analysis' operation conditions, the EI of released CO2 value can be reduced by 8.4% by carbon capture and storage. Thus, the details of the analyzes performed for the plant are expected to guide the researchers. (c) 2021 Published by Elsevier Ltd.

Kaynak

RENEWABLE ENERGY

Cilt

185

Bağlantı

https://doi.org/10.1016/j.renene.2021.12.097
https://hdl.handle.net/20.500.12809/9946

Koleksiyonlar

  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu [104]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.