Basit öğe kaydını göster

dc.contributor.authorDemirci, İsmail Mehmet
dc.contributor.authorBalcı, Yasemin
dc.contributor.authorKadı, Gülsüm
dc.contributor.authorSeçkin, çetin
dc.contributor.authorTosun, Kürşad
dc.date.accessioned2022-05-17T07:57:30Z
dc.date.available2022-05-17T07:57:30Z
dc.date.issued2021en_US
dc.identifier.citationDEMİRCİ İ. M,BALCI Y,KADI G,SEÇKİN Ç,TOSUN K (2021). Oral Antiseptik Spreylerdeki Etanolün Nefeste Alkol Ölçümü Üzerine Etkisi. Adli Tıp Bülteni, 26(1), 1 - 7. Doi: 10.17986/blm.1306en_US
dc.identifier.issn1300-865X / 2149-4533
dc.identifier.urihttps://doi.org/10.17986/blm.1306
dc.identifier.urihttps://hdl.handle.net/20.500.12809/9976
dc.description.abstractAmaç: Trafikte alkolmetre ile denetleme yapılırken, ağız içi alkol nedeniyle nefes alkol konsantrasyonu daha yüksek çıkabilmektedir. KarayollarıTrafik Yönetmeliği’ne göre, teknik cihazla yapılan ölçüm sonucuna itiraz edilmesi durumunda tekrar ölçüm yapılmamaktadır. Bu çalışmada oralantiseptik sprey kullanımının, alkolmetre yardımı ile ölçülen nefes alkol düzeylerine etkisi ve zamanla ilişkisinin belirlenmesi amaçlanmıştır.Yöntem: Bu çalışma, 30 sağlıklı gönüllünün sonuçlarını içermektedir. Çalışmada etanol içeren üç oral sprey ve taşınabilir alkolmetrekullanılmıştır. Her kişi için oral sprey kullanımı öncesi (Tönce) solunum alkol konsantrasyonu (SAK) değeri kaydedilmiştir. Bireylerden her spreyiçin, 3 kere ağız içine püskürttükten hemen sonra alkolmetreye üflemesi istenmiştir. Bu şekilde SAK 0. dakika (T0) değeri elde edilmiştir. Üçdakika sonra (T3) ve 5 dakika sonra (T5) iki kez daha ölçümler tekrarlanmıştır.Bulgular: Gönüllülerin 14’ü kadın ve 16’sı erkekti. Çalışmanın yapılandırılması doğrultusunda, Tönce, T0, T3, T5 SAK değerleri ölçülüp kaydedilmişve tabloda gösterilmiştir. T0 SAK değerleri; 1. spreyde minimum (min): 0,82, maksimum (maks): 4,25; 2. spreyde min: 1,05, maks: 4,25; 3.spreyde min: 1,32, maks: 4,25 promil olarak ölçülmüştür. T0’dan T3’e ve T5’e geçtikçe SAK medyan değerleri sıfıra yaklaşmıştır. Her üç ilaç içinT3 değerlerinin, T0 değerlerinden ve T5 değerlerinin, T0 ve T3 değerlerinden daha düşük olduğu görülmüştür (p<0,001). Sprey kullanımındansonraki 5. dakikada ölçülen en yüksek solunum alkol düzeyi 0,37 promil olup yasal seviyenin (0,5 promil) altına indiği gözlenmiştir.Sonuç: Bu araştırma, etanol içeren spreylerin alkolmetre sonuçlarını değiştirebildiğini göstermiştir. Alkolmetre ile nefeste alkol ölçümünün oralantiseptik spreylerin kullanımına bağlı ağız boşluğundaki rezidü etanolden etkilendiği, bununla birlikte hızla elimine olup 5. dakikada yasalsınırın altına indiği görülmüştür.en_US
dc.description.abstractObjective: Breath alcohol concentration (BrAC) in routine traffic control might be higher due to reasons which affect mouth alcohol concentration. According to Highways Traffic Regulation, there is no possibility to recheck/remeasure with technical device. In this study, we aimed to answer firstly how oral antiseptic sprays affect BrAC and then what correlation there is between BrACs and time. Methods: This study included 30 healthy volunteers’ results. In this study, three oral antiseptic sprays (OAS) containing ethanol and a portable electrochemical sensorized breathalyzer were used. BrAC (Tbefore), which is used before spray, was checked and saved for each subject. Subjects sprayed 3 puffs of OAS into their mouths and immediately underwent a breathalyzer examination to evaluate BrAC (T0). Two more examinations were conducted 3 minutes later (T3) and 5 minutes later (T5). Results: The highest BrAC value (4.25 permille) was attained at T0 in 12 subjects; all BrAC values (before spray use) were checked and saved. The BrAC median values decreased under legal limit zero as time passed by from T0 to T3 and T5). T3 values were lower than the corresponding T0 values for all three medications and all T5 values were lower than corresponding T0 and T3 values (all p<0.001). Conclusion: This research study shows that ethanol containing sprays may alter the results of a single breathalyzer test. Based on our results, the BrAC values are indeed affected by residual ethanol in the oral cavity due to prior use of OAS and this explains why BrAC decrease rate is remarkable.en_US
dc.item-language.isoturen_US
dc.publisherAdli Tıp Uzmanları Derneğien_US
dc.relation.isversionof10.17986/blm.1306en_US
dc.item-rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectNefeste alkol ölçümüen_US
dc.subjectOral antiseptik spreyen_US
dc.subjectAlkolmetreen_US
dc.subjectBreath alcohol levelen_US
dc.subjectOral antiseptic spraysen_US
dc.subjectBreathalyzeren_US
dc.titleOral Antiseptik Spreylerdeki Etanolün Nefeste Alkol Ölçümü Üzerine Etkisien_US
dc.item-title.alternativeEffect of Ethanol in Oral Antiseptic Sprays on Breath Alcohol Measurementen_US
dc.item-typearticleen_US
dc.contributor.departmentMÜ, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümüen_US
dc.contributor.authorID0000-0002-5995-9924en_US
dc.contributor.institutionauthorBalcı, Yasemin
dc.identifier.volume26en_US
dc.identifier.issue1en_US
dc.identifier.startpage1en_US
dc.identifier.endpage7en_US
dc.relation.journalAdli Tıp Bültenien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster