• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Muğla
  • Fakülteler
  • Fen Fakültesi
  • Kimya Bölümü Koleksiyonu
  • Öğe Göster
  •   DSpace@Muğla
  • Fakülteler
  • Fen Fakültesi
  • Kimya Bölümü Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Development of MoS2 and Au nanoparticle including disposable CEA-based immuno-cytosensor platforms

Thumbnail

Göster/Aç

Tam metin / Full text (2.196Mb)

Tarih

2022

Yazar

Altuntaş, Derya Bal
Nalkıran, Hatice S.
Aslan, Sema
Yolcu, Zuhal

Üst veri

Tüm öğe kaydını göster

Künye

Bal Altuntaş, D., Nalkıran, H.S., Aslan, S. et al. Development of MoS2 and Au nanoparticle ıncluding disposable CEA-based immuno-cytosensor platforms. Chem. Pap. (2022). https://doi.org/10.1007/s11696-022-02240-x

Özet

In this study, an electrochemical biosensor for determination of Carcinoembryonic antigen (CEA) biomarker using human breast ductal adenocarcinoma (MCF-7) and human ovarian adenocarcinoma (SK-OV-3) cancer cells was presented. Disposable pencil graphite electrodes (PGE) has been modified with Au nanoparticle (Au NP) and MoS2 nanostructure dispersed chitosan (Cs) matrix. Therefore, the electrochemical interaction between the antibody-electrode surface was facilitated. Under optimal conditions, the immunosensor exhibited high sensitivity toward CEA biomarker in the low concentration range 0.01-10 ng mL(-1), with the detection limit of 1.93 ng mL(-1) and relative standard deviation of 4.65 (n = 5). The results indicated that even very small changes in CEA concentration can be sensed with the presented system. Also, recovery of the immunosensor found as 98 +/- 3% in the real sera samples containing dopamine and ascorbic acid. It has a great potential in the clinical screening of divergent cancer biomarkers. Experiments were conducted to determine the number of normal cell hGF and cancer cells adhered and attached on immuno-cytosensor surfaces. CEA-positive MCF-7 cells have shown great potential for adhesion and attachment to MoS2/Cs/Au/Anti-CEA/CEA surface better than CEA-negative cells. The developed immuno-cytosensor exhibited very promising results for the future biosensor studies.

Kaynak

CHEMICAL PAPERS

Bağlantı

https://doi.org/10.1007/s11696-022-02240-x
https://hdl.handle.net/20.500.12809/10002

Koleksiyonlar

  • Kimya Bölümü Koleksiyonu [352]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.