• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Muğla
  • Meslek Yüksekokulları
  • Köyceğiz Sağlık Hizmetleri Meslek Yüksekokulu
  • Sağlık Bakım Hizmetleri Bölümü Koleksiyonu
  • Öğe Göster
  •   DSpace@Muğla
  • Meslek Yüksekokulları
  • Köyceğiz Sağlık Hizmetleri Meslek Yüksekokulu
  • Sağlık Bakım Hizmetleri Bölümü Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Gait assessment in shaped pathways: The test-retest reliability and concurrent validity of the figure of eight test and L test in multiple sclerosis patients without mobility aids

Thumbnail

Göster/Aç

Tam metin / Article (811.5Kb)

Tarih

2022

Yazar

Özden, Fatih
Özkeskin, Mehmet
Ar, Ege
Yüceyar, Nur

Üst veri

Tüm öğe kaydını göster

Künye

Özden, F., et al. "Gait Assessment in Shaped Pathways: The Test-Retest Reliability and Concurrent Validity of the Figure of Eight Test and L Test in Multiple Sclerosis Patients without Mobility Aids." Multiple Sclerosis and Related Disorders, vol. 65, 2022. doi:10.1016/j.msard.2022.103998.

Özet

Purpose: To our knowledge, no other studies have demonstrated the reliability and validity of the Figure of Eight Walking Test (F8WT) and L Test in patients with multiple sclerosis (MS). The aim of the study was to prove the test-retest reliability and concurrent validity of the F8WT and L Test in patients with MS. Methods: A cross-sectional study was conducted with 52 patients with MS. A clinical neurologist evaluated patients by Expanded Disability Status Scale (EDSS). Participants completed the F8WT, L Test, Timed Up and Go Test (TUG), and Timed 25-Foot Walk Test (T25FW) in the first assessment session. Then, the F8WT and L Test was retested one hour later. The same evaluator completed all of the assessments. Results: The ICC of both tests were excellent (ICCF8WT: 0.972, ICCL Test: 0.986). F8WT and L test measurement did not show a systematic bias and were within the agreement limits. The Standard Error of Measurement (SEM95) and Minimal Detectable Change (MDC95) values of the F8WT was 0.58 and 1.60, respectively. Besides, L Test's SEM95 and MDC95 were 0.59 and 1.63. The correlation between F8WT with TUG, T25FW and EDSS was 0.849, 0.810 and 0.453. On the other hand, the L test's correlation coefficient with TUG, T25FW and EDSS 0.682, 0.706 and 0.535, respectively (p < 0.01). Individuals with “EDSS ≤ 1″ had statistically significantly better L-test and F8WT scores than those with “EDSS: 1 to 4.5″ (p < 0.01). Conclusion: F8WT and L Test is a valid and reliable physical performance test in MS patients without mobility aids. Both tests demonstrate advanced gait assessment in L and 8 shaped pathways to provide more comprehensive evaluation than horizontal pathways.

Kaynak

Multiple Sclerosis and Related Disorders

Cilt

65

Bağlantı

https://doi.org/10.1016/j.msard.2022.103998
https://hdl.handle.net/20.500.12809/10133

Koleksiyonlar

  • Sağlık Bakım Hizmetleri Bölümü Koleksiyonu [91]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • TR-Dizin İndeksli Yayınlar Koleksiyonu [3005]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.