• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace@Muğla
  • Fakülteler
  • Tıp Fakültesi
  • Eğitim ve Araştırma Hastanesi Koleksiyonu
  • View Item
  •   DSpace@Muğla
  • Fakülteler
  • Tıp Fakültesi
  • Eğitim ve Araştırma Hastanesi Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis

Thumbnail

View/Open

Tam metin / Article (1.534Mb)

Access

info:eu-repo/semantics/openAccess

Date

2022

Author

Kaşıkçı, Murat
Karalezli, Aylin
Eroğul, Özgür
Gobeka, Hamidu Hamisi

Metadata

Show full item record

Citation

Kasıkcı M, Karalezli A, Eroğul Ö, Gobeka HH. Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis. Rom J Ophthalmol. 2022 Jul-Sep;66(3):245-256. doi: 10.22336/rjo.2022.47. PMID: 36349169; PMCID: PMC9585500.

Abstract

Purpose: Slowing ectasia progression is critical for maintaining visual potential in keratoconus (KC), for which various therapeutic approaches have been implemented. A Pentacam Scheimpflug imaging device was used to quantify contact lens (CL)-related changes in keratoconus corneal topographic indices. Methods: Thirty KC patients (group 1; 60 eyes) were using one of the three CL (rigid gas-permeable CL (RGPCL)-10, hybrid CL (HCL)-10, and scleral CL (SCL)-10 patients). A control group included 30 KC patients (group 2; 60 eyes) not using CLs due to intolerance or inappropriateness. The Pentacam® HR Scheimpflug imaging device was used to measure topographic indices such as Km anterior, Km posterior, K max, corneal thickness (CT, corneal central, apex, and thinnest), corneal volume (CV), anterior chamber volume (ACV), and anterior chamber depth (ACD) at baseline, 3rd, 6th, and 12th months. Results: The mean ages for groups 1 and 2 were 32±10 and 31±09 years, respectively. Group 1 had a lower but statistically significant change in K max than group 2 (p<0.038). Also, group 1 had a minor but non-significant decrease in anterior and posterior keratometry values compared to group 2 (pKm ant. right/ left eye = 0.063/ 0.065 and 0.087/ 0.094, respectively). RGPCL users had significant changes in central CT, thinnest CT and ACD (p<0.041). SCL users had more stable changes than other CLs for the thinnest CT along with significant changes in K max, pachy apex and ACV (p<0.036). HCL users had significantly higher K max stability (p<0.039). Conclusion: Regular use of appropriate therapeutic CLs may help to stabilize corneal deformity, thereby slowing changes in corneal topographic indices in KC.

Source

Romanian Journal of Ophthalmology

Volume

66

Issue

3

URI

https://hdl.handle.net/20.500.12809/10380

Collections

  • Eğitim ve Araştırma Hastanesi Koleksiyonu [215]
  • PubMed İndeksli Yayınlar Koleksiyonu [2082]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Muğla

by OpenAIRE
Advanced Search

Open Policy Finder

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Guide|| Instruction || Library || Muğla Sıtkı Koçman University || OAI-PMH ||

Muğla Sıtkı Koçman University, Muğla, Turkey
If you find any errors in content, please contact:

Creative Commons License
Muğla Sıtkı Koçman University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.