• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Muğla
  • Fakülteler
  • Teknoloji Fakültesi
  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu
  • Öğe Göster
  •   DSpace@Muğla
  • Fakülteler
  • Teknoloji Fakültesi
  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Life cycle cost assessment for thermal insulation of above-ground spherical container with different capacities in hot fluid storage processes

Thumbnail

Göster/Aç

Tam metin / Article (7.216Mb)

Tarih

2023

Yazar

Karaca Dolgun, Gülşah
Keçebaş, Ali
Ertürk, Mustafa
Daşdemir, Ali

Üst veri

Tüm öğe kaydını göster

Künye

Karaca Dolgun, G., A. Keçebaş, M. Ertürk, and A. Daşdemir. 2023. "Life Cycle Cost Assessment for Thermal Insulation of Above-Ground Spherical Container with Different Capacities in Hot Fluid Storage Processes." Journal of Cleaner Production 403. doi:10.1016/j.jclepro.2023.136875

Özet

Due to environmental and economic reasons, thermal energy saving has gained more importance especially in industry. This study is concerned with the application of insulation to improve thermal energy storage in spherical shaped containers positioned high above the ground. For this purpose, the thickness of the insulation applied to spherical containers of different diameters was optimized for convection and radiation heat transfer using life cycle cost analysis. In Turkey, the mechanism of storing the thermal energy of water at different temperatures in four different climatic conditions in Turkey (Ankara, Antalya, Erzurum, and Istanbul) in a container has been investigated. The results of the study show that the optimum insulation thickness and energy savings rise as the water storage temperature and the diameter of the container increase. While there is a 46% increase in the optimum insulation thickness for the vessel diameter from 0.5m to 3m in 20 °C water, a 69% increase is achieved in 100 °C water. Similarly, 85% and 114% increases were found for the optimum insulation thickness from 20 °C to 100 °C for 0.5m and 3m, respectively. In climates with the lowest heating degree-hours (Antalya), the highest energy savings are achieved with the lowest insulation thickness. To accurately determine seasonal storage heat load, a revised heating degree-hour method using hourly solar-air temperature data is recommended. This provides a 13% increase in energy savings.

Kaynak

Journal of Cleaner Production

Cilt

403

Bağlantı

https://doi.org/10.1016/j.jclepro.2023.136875
https://hdl.handle.net/20.500.12809/10636

Koleksiyonlar

  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu [104]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.