• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace@Muğla
  • Fakülteler
  • Teknoloji Fakültesi
  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu
  • View Item
  •   DSpace@Muğla
  • Fakülteler
  • Teknoloji Fakültesi
  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Life cycle cost assessment for thermal insulation of above-ground spherical container with different capacities in hot fluid storage processes

Thumbnail

View/Open

Tam metin / Article (7.216Mb)

Date

2023

Author

Karaca Dolgun, Gülşah
Keçebaş, Ali
Ertürk, Mustafa
Daşdemir, Ali

Metadata

Show full item record

Citation

Karaca Dolgun, G., A. Keçebaş, M. Ertürk, and A. Daşdemir. 2023. "Life Cycle Cost Assessment for Thermal Insulation of Above-Ground Spherical Container with Different Capacities in Hot Fluid Storage Processes." Journal of Cleaner Production 403. doi:10.1016/j.jclepro.2023.136875

Abstract

Due to environmental and economic reasons, thermal energy saving has gained more importance especially in industry. This study is concerned with the application of insulation to improve thermal energy storage in spherical shaped containers positioned high above the ground. For this purpose, the thickness of the insulation applied to spherical containers of different diameters was optimized for convection and radiation heat transfer using life cycle cost analysis. In Turkey, the mechanism of storing the thermal energy of water at different temperatures in four different climatic conditions in Turkey (Ankara, Antalya, Erzurum, and Istanbul) in a container has been investigated. The results of the study show that the optimum insulation thickness and energy savings rise as the water storage temperature and the diameter of the container increase. While there is a 46% increase in the optimum insulation thickness for the vessel diameter from 0.5m to 3m in 20 °C water, a 69% increase is achieved in 100 °C water. Similarly, 85% and 114% increases were found for the optimum insulation thickness from 20 °C to 100 °C for 0.5m and 3m, respectively. In climates with the lowest heating degree-hours (Antalya), the highest energy savings are achieved with the lowest insulation thickness. To accurately determine seasonal storage heat load, a revised heating degree-hour method using hourly solar-air temperature data is recommended. This provides a 13% increase in energy savings.

Source

Journal of Cleaner Production

Volume

403

URI

https://doi.org/10.1016/j.jclepro.2023.136875
https://hdl.handle.net/20.500.12809/10636

Collections

  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu [104]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Muğla

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Guide|| Instruction || Library || Muğla Sıtkı Koçman University || OAI-PMH ||

Muğla Sıtkı Koçman University, Muğla, Turkey
If you find any errors in content, please contact:

Creative Commons License
Muğla Sıtkı Koçman University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.