Basit öğe kaydını göster

dc.contributor.authorAtasoy, Muhammet
dc.date.accessioned2023-07-05T13:29:11Z
dc.date.available2023-07-05T13:29:11Z
dc.date.issued2023en_US
dc.identifier.citationAtasoy M. Development of a New Sensitive Method for Lead Determination by Platinum-Coated Tungsten-Coil Hydride Generation Atomic Absorption Spectrometry. ACS Omega. 2023 Jun 9;8(25):22866-22875. doi: 10.1021/acsomega.3c01856. PMID: 37396250; PMCID: PMC10308594.en_US
dc.identifier.urihttps://doi.org/10.1021/acsomega.3c01856
dc.identifier.urihttps://hdl.handle.net/20.500.12809/10807
dc.description.abstractA novel very sensitive and rapid analytical method was improved where gaseous lead formed was transported to and trapped on an externally heated platinum-coated tungsten-coil atom trap for in situ preconcentration. The analytical performance of the developed method with the graphite furnace atomic absorption spectrometry (GFAAS) method was compared. All critical parameters affecting the performance of both methods were optimized. The limit of quantitation (LOQ) was found as 11.0 ng L-1 and the precision was 2.3% in terms of percent relative standard deviation (RSD%). Characteristic concentration (Co) of the developed trap method was indicating a 32.5-fold enhancement in sensitivity compared to the GFAAS method. In order to investigate the surface morphology of the W-coil, scanning electron microscope-energy-dispersive X-ray (SEM-EDS) analyzes were performed. The accuracy of the trap method was tested by certified reference materials: NIST SRM 1640a (the elements in natural water) and DOLT:5 (dogfish liver). Interferences from other hydride-forming elements were investigated. Application of the trap method was demonstrated by the analysis of some drinking water and fish tissue samples. The t test was applied to drinking water samples, and the results indicated that there was no statistically significant error.en_US
dc.item-language.isoengen_US
dc.publisherPMCen_US
dc.relation.isversionof10.1021/acsomega.3c01856en_US
dc.item-rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPlatinum-coated tungsten-coilen_US
dc.titleDevelopment of a New Sensitive Method for Lead Determination by Platinum-Coated Tungsten-Coil Hydride Generation Atomic Absorption Spectrometryen_US
dc.item-typearticleen_US
dc.contributor.departmentMÜ, Muğla Meslek Yüksekokulu, Kimya ve Kimyasal İşleme Teknolojileri Bölümüen_US
dc.contributor.authorID0000-0003-4312-1876en_US
dc.contributor.institutionauthorAtasoy, Muhammet
dc.identifier.volume8en_US
dc.identifier.issue25en_US
dc.relation.journalACS Omegaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster