• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Muğla
  • Fakülteler
  • Teknoloji Fakültesi
  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu
  • Öğe Göster
  •   DSpace@Muğla
  • Fakülteler
  • Teknoloji Fakültesi
  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Design and experimental analysis of a parallel-flow photovoltaic-thermal air collector with finned latent heat thermal energy storage unit

Thumbnail

Göster/Aç

Tam metin / Article (9.096Mb)

Tarih

2023

Yazar

Yağız Gürbüz, Emine
Şahinkesen, İstemihan
Tuncer, Azim Doğuş
Keçebaş, Ali

Üst veri

Tüm öğe kaydını göster

Künye

GÜRBÜZ, Emine Yağız, et al. Design and experimental analysis of a parallel-flow photovoltaic-thermal air collector with finned latent heat thermal energy storage unit. Renewable Energy, 2023, 119154.

Özet

In this work, it is aimed to improve the performance of a photovoltaic-thermal (PVT) air collector using finned latent heat thermal energy storage unit. In this regard, four different types of parallel-flow PVT (PPVT) systems have been designed, manufactured and tested including a conventional PPVT, a PPVT with paraffin-based thermal energy storage unit, a PPVT with 3-finned storage unit and a PPVT with 6-finned storage unit. A parallel-flow collector geometry has been designed to convey excess heat from both surfaces of the photovoltaic panel in the systems. Moreover, the effect of increasing the number of fins in the storage system in the PPVT on the performance has been analyzed within the scope of this work and the developed systems have been tested simultaneously. According to the experimentally obtained findings, overall efficiency value of the PPVT was improved from 55.83% to 76.79% using thermal energy storage with 6-fins. The performance ratio and sustainability index values were obtained between 0.64-0.76 and 1.0277–1.0474, respectively. Enviro-economic analysis has been performed and payback periods of the systems were attained between 0.991 and 1.146 years. Also, employing 6-finned storage unit in the PPVT upgraded the annual carbon dioxide savings as 33.71% in comparison to the unmodified PPVT.

Kaynak

Renewable Energy

Cilt

217

Bağlantı

https://doi.org/10.1016/j.renene.2023.119154
https://hdl.handle.net/20.500.12809/10925

Koleksiyonlar

  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu [104]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.