Basit öğe kaydını göster

dc.contributor.authorÖzyurt, Vasfiye Hazal
dc.contributor.authorÇaylayık, Nil Su
dc.contributor.authorÇitil, Burak Ekrem
dc.contributor.authorTürkiş, Fulden Cantaş
dc.contributor.authorAnık, Ülkü
dc.date.accessioned2026-06-24T07:50:40Z
dc.date.available2026-06-24T07:50:40Z
dc.date.issued2026en_US
dc.identifier.citationV. H. Özyurt, N. S. Çaylayik, B. E. Çitil, F. C. Türkiş, and Ü. Anik, “ A Hybrid Nanomaterial-Based Electrochemical Sensor for Melatonin Measurement in Human Saliva: A Diagnostic Tool for Anxiety Disorder.” ChemistrySelect 11, no. 22 (2026): e73630. https://doi.org/10.1002/slct.73630en_US
dc.identifier.urihttps://doi.org/10.1002/slct.73630
dc.identifier.urihttps://hdl.handle.net/20.500.12809/11220
dc.description.abstractSince the diagnosis of anxiety disorder is primarily based on questionnaires, accurate identification of the disorder can be challenging. Melatonin has been identified as a potential biomarker for the detection of anxiety disorders. By targeting this biomarker, it will be possible to get more accurate results and diagnose anxiety disorder more properly. In this study, a carbon screen-printed electrode modified with multi-walled carbon nanotube-gold-platinum (MWCNT-Au-Pt) nanocomposite-based electrochemical sensor was developed for the detection of melatonin. To enhance the sensor's performance, key experimental parameters-including the amount of MWCNT-Au-Pt nanoparticle and the pH of the solution-were systematically optimized. The sensor exhibited two linear response ranges for melatonin: from 0.5 to 50 & micro;M with a limit of detection (LOD) of 0.23 & micro;M, and from 100 to 1000 & micro;M with an LOD of 2.14 & micro;M. The sensor's specificity was evaluated in the presence of potential interfering substances. It was subsequently applied successfully to the detection of melatonin in 25 real human saliva samples. As a result, the first MWCNT-Au-Pt modified electrochemical sensor for melatonin detection, which will lead to proper anxiety disorder diagnosis, was fabricated.en_US
dc.language.isoengen_US
dc.publisherWILEYen_US
dc.relation.isversionof10.1002/slct.73630en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectanxiety disorderen_US
dc.subjecthuman salivaen_US
dc.subjectmelatoninen_US
dc.subjectsensoren_US
dc.titleA Hybrid Nanomaterial-Based Electrochemical Sensor for Melatonin Measurement in Human Saliva: A Diagnostic Tool for Anxiety Disorderen_US
dc.typearticleen_US
dc.contributor.departmentMÜ, Fen Fakültesi, Kimya Bölümüen_US
dc.contributor.authorID0000-0003-2524-5381en_US
dc.contributor.authorID0009-0004-4727-1657en_US
dc.contributor.authorID0000-0003-1043-1763en_US
dc.contributor.authorID0000-0002-7018-7187en_US
dc.contributor.authorID0000-0002-3607-7208en_US
dc.contributor.institutionauthorÖzyurt, Vasfiye Hazal
dc.contributor.institutionauthorÇaylayık, Nil Su
dc.contributor.institutionauthorÇitil, Burak Ekrem
dc.contributor.institutionauthorTürkiş, Fulden Cantaş
dc.contributor.institutionauthorAnık, Ülkü
dc.identifier.volume11en_US
dc.identifier.issue22en_US
dc.relation.journalChemistrySelecten_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster