• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Muğla
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace@Muğla
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Comparison of the planimetry and point-counting methods for estimating kidney volume using magnetic resonance imaging

Thumbnail

Göster/Aç

Tam metin / Full text (1.035Mb)

Tarih

2016

Yazar

Sağıroğlu, Ayşe
Acer, Niyazi
Demir, Mehmet
Yıldırım, Birdal
Çamurdanoğlu, Mehmet

Üst veri

Tüm öğe kaydını göster

Özet

Introduction: Kidney volume (KV) is an important parameter for clinical assessment of patients with diabetes or renal artery stenosis and for assessment of kidney transplant candidates. The purpose of this study was to compare KV estimations obtained by using the Cavalieri principle combined with point-counting and planimetry techniques. In addition, we evaluated the results to construct a confidence interval value for KV according to a new approach. Methods: The KV of 15 volunteers (30 kidneys) with no known history of renal diseases. Their age ranged from 18 to 25 years. A 3D-fast spoiled gradient-echo dual echo array spatial sensitivity encoding technique axial plan was performed using 1.5-T scanner. We used magnetic resonance (MR) images using the point-counting and planimetry methods to estimate KV. Results: Kidney volumes obtained by the two different methods were not statistically different and correlated well with each other. The reference values of KV parameters with 95% confidence interval (CI) for lower and upper mean values were 121.50 cm(3) and 144.90 cm(3) respectively. The mean coefficient of error (CE) for KV estimates derived from the stereologic technique was between 0.5 and 1%. Discussion: For accurate and precise estimation of KV, MR imaging with use of the two methods: should be preferred using our MR protocol. We also evaluated a satisfactory predicted CE values and this provided a relatively narrow confidence interval. (C) 2017 Anatomical Society of India. Published by Elsevier, a division of RELX India, Pvt. Ltd. All rights reserved.

Kaynak

Journal of the Anatomical Society of India

Cilt

65

Sayı

2

Bağlantı

https://doi.org/10.1016/j.jasi.2017.02.005
https://hdl.handle.net/20.500.12809/2252

Koleksiyonlar

  • Cerrahi Tıp Bilimleri Bölümü Koleksiyonu [543]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.