• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Muğla
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace@Muğla
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Multiple Energy Synchrotron Biomedical Imaging System- Preliminary Results

Thumbnail

Göster/Aç

Tam metin / Congresses object (104.8Kb)

Tarih

2015

Yazar

Bassey, B.
Mercedes, M.
Samadi, N.
Belev, G.
Karanfil, Cahit
Chapman, D.

Üst veri

Tüm öğe kaydını göster

Özet

The drive to improve and expand the amount of information extracted from various imaging modalities has led to the use of multiple (usually two) x-ray photon energies in computed tomography clinical systems. With the use of a single photon energy, the ability to differentiate soft from hard tissues is a problem which multiple energy imaging can solve. The continuous spectrum available from synchrotron light facilities provides a nearly an ideal source for multiple energy imaging. For living biological subjects a multiple energy system that can extract multiple endogenous or induced contrast materials as well as water and bone images would be ideal. A novel bent Laue single crystal monochromator that has a wide angularly dispersed energy range (polychromator) has been developed to explore the use of multiple energies simultaneously for biomedical imaging at the Biomedical Imaging and Therapy beamline at the Canadian Light Source. Using the 311 reflection from a 511 silicon crystal wafer bent to a radius of 95 cm, the system prepares a 0.5 mm wide focused polychromatic x-ray beam with a spectral range of 27 keV to 43 keV, covering both the iodine and barium K-edges of 33.17 keV and 37.44 keV, respectively. As an example use, test objects with iodine and barium (common contrast agents used in clinical imaging) along with water and bone were imaged and successfully extracted independent quantifiable images of these four materials. The biomedical imaging system is presented with emphasis on the polychromator used to prepare the imaging beam.

Kaynak

World Congress on Medical Physics and Biomedical Engineering, 2015, Vols 1 and 2

Cilt

51

Bağlantı

https://doi.org/10.1007/978-3-319-19387-8_60
https://hdl.handle.net/20.500.12809/3169

Koleksiyonlar

  • Fizik Bölümü Koleksiyonu [189]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.