dc.contributor.author | Merkoci, Arben | |
dc.contributor.author | Anık, Ülkü | |
dc.contributor.author | Cevik, Serdar | |
dc.contributor.author | Cubukcu, Meliha | |
dc.contributor.author | Guix, Maria | |
dc.date.accessioned | 2020-11-20T16:34:00Z | |
dc.date.available | 2020-11-20T16:34:00Z | |
dc.date.issued | 2010 | |
dc.identifier.issn | 1040-0397 | |
dc.identifier.uri | https://doi.org/10.1002/elan.200970002 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12809/4547 | |
dc.description | anik, ulku/0000-0002-3607-7208; Merkoci, Arben/0000-0003-2486-8085; Noguera, Maria Guix/0000-0002-5219-6434 | en_US |
dc.description | WOS: 000280172900004 | en_US |
dc.description.abstract | Mushroom tissue was immobilized onto plain screen printed electrode (SPE) and multiwalled carbon nanotube (MWCNT) modified SPE (SPE/MWCNT) via bismuth (Bi) deposition. By this way. SPE/Bi/Tissue and SPE/MWCNT/Bi/Tissue biosensors for phenol detection were obtained. UV-visible spectroscopy and SEM were utilized for explain the immobilization procedure. After optimizing working parameters, both biosensors were compared in terms of analytical characteristics. Linear range of response were found as 5-100 mu M for SPE/Bi/Tissue and 2- 200 mu M for SPE/MWCNT/Bi/Tissue while detection limits were calculated as 0.48 mu M and 1.1.7 mu M for SPE/Bi/ Tissue and SPE/MWCNT/Bi/Tissue respectively. Developed systems were also applied for phenol detection in synthetically prepared waste water sample and very promising results were obtained. | en_US |
dc.description.sponsorship | MICINN (Madrid, Spain)Spanish Government [MAT2008-03079/NAN, BES-2009-023939]; ICREAICREA Funding Source: Custom | en_US |
dc.description.sponsorship | We acknowledge funding from the MICINN (Madrid, Spain) for the Projects MAT2008-03079/NAN and for the scholarship BES-2009-023939 given to M. Guix. | en_US |
dc.item-language.iso | eng | en_US |
dc.publisher | Wiley-V C H Verlag Gmbh | en_US |
dc.item-rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Bi-Film | en_US |
dc.subject | Mushroom Tissue | en_US |
dc.subject | Phenol Biosensor | en_US |
dc.subject | Screen Printed Electrode | en_US |
dc.subject | Biosensors | en_US |
dc.subject | Bismuth | en_US |
dc.title | Bismuth Film Combined with Screen-Printed Electrode as Biosensing Platform for Phenol Detection | en_US |
dc.item-type | article | en_US |
dc.contributor.department | MÜ | en_US |
dc.contributor.departmentTemp | [Merkoci, Arben; Guix, Maria] ICN, Nanobioelect & Biosensors Grp, Barcelona, Catalonia, Spain -- [Merkoci, Arben] ICREA, Barcelona, Spain -- [Anik, Ulku; Cevik, Serdar; Cubukcu, Meliha] Mugla Univ, Fac Arts & Sci, Dept Chem, TR-48000 Kotekli Mugla, Turkey -- [Cubukcu, Meliha] Ege Univ, Dept Chem, Fac Sci, TR-35100 Izmir, Turkey -- [Guix, Maria] Univ Autonoma Barcelona, Dept Chem, Bellaterra 08193, Catalonia, Spain | en_US |
dc.identifier.doi | 10.1002/elan.200970002 | |
dc.identifier.volume | 22 | en_US |
dc.identifier.issue | 13 | en_US |
dc.identifier.startpage | 1429 | en_US |
dc.identifier.endpage | 1436 | en_US |
dc.relation.journal | Electroanalysis | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |