A novel analytical system involving hydride generation and gold-coated W-coil trapping atomic absorption spectrometry for selenium determination at ng l(-1) level

Date

2008

Author

Kula, I.
Arslan, Y.
Bakirdere, S.
Ataman, O. Y.

Metadata

Show full item record

Abstract

A novel analytical technique was developed where gaseous hydrogen selenide formed by sodium tetra hydrobora te reduction is transported to and trapped on a resistively heated gold-coated W-coil atom trap for in situ preconcentration. Gold coating on W-coil was prepared by using an organic solution of Au. The atom trap is held at 165 degrees C during the collection stage and is heated up to 675 degrees C for revolatilization; analyte species formed are transported to an externally heated quartz T-tube where the atornization takes place and the transient signal is obtained. The carrier gas consisted of 112.5 ml min' At with 75 ml min(-1) H-2 during the collection step and 112.5 ml min(-1) At with 450 ml min(-1) H-2 in the revolatilization step. The half width of the transient signal obtained is less than 0.5 s. The RSD for the measurements was found to be 3.9% (n = 11) for 0.10 mu g l(-1) Se using peak height measurements. The calibration plot for 27.0 ml of sample collected in 4.0 min using a flow rate of 6.75 ml min(-1) was linear between 0.13 and 2.0 mu g l(-1) of Se. The limit of detection (3 s) is 39 ng l(-1). The enhancement factor for the characteristic concentration (Co) was found to be 20.1 when compared to conventional hydride generation atomic absorption spectrometry system without trap. In order to check the accuracy of the method. standard reference material, natural water NIST 1640 was employed; the result was found to be in good agreement with the certified value at the 95% confidence level. (c) 2008 Elsevier B.V. All rights reserved.

Source

Spectrochimica Acta Part B-Atomic Spectroscopy

Volume

63

Issue

8

URI

https://doi.org/10.1016/j.sab.2008.03.020
https://hdl.handle.net/20.500.12809/4936

Collections

  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Muğla

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Guide|| Instruction || Library || Muğla Sıtkı Koçman University || OAI-PMH ||

Muğla Sıtkı Koçman University, Muğla, Turkey
If you find any errors in content, please contact:

Creative Commons License
Muğla Sıtkı Koçman University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.