Basit öğe kaydını göster

dc.contributor.authorÖzden, Fatih
dc.contributor.authorCoşkun, Gökhan
dc.contributor.authorBakırhan, Serkan
dc.date.accessioned2020-11-20T16:49:53Z
dc.date.available2020-11-20T16:49:53Z
dc.date.issued2020
dc.identifier.issn0531-5565
dc.identifier.urihttps://doi.org/10.1016/j.exger.2020.111143
dc.identifier.urihttps://hdl.handle.net/20.500.12809/6193
dc.description.abstractPurpose: The aim of the study was to determine the test-retest reliability and concurrent validity of the five times sit to stand test (FTST) and step test (ST) in older adults with total hip arthroplasty (THA). Methods: A cross-sectional and prospective study was carried out with 32 unilateral total hip arthroplasty patients. FTST, ST, and Timed Up & Go Test were evaluated at the first evaluation session. The test-retest reliability was evaluated by performing two repetitions of the FTST and ST. Besides, the functional status of the patients was evaluated with the Harris Hip Score (HHS). The test-retest reliability of the FTST and ST were assessed by the intraclass correlation coefficient (ICC). In the concurrent validity analysis, the Pearson correlation coefficient was analyzed. In addition, the standard error of measurement (SEM95) and minimal detectable change (MDC95) values of the FTST and ST were also calculated. Results: The mean age of the participants was 75.4 ± 10.3 years. The ICC score of FTST, ST (right) and ST (left) were 0.987, 0.908 and 0.846, respectively. SEM95 and MDC95 values of the FTST were 1.05 and 2.91, respectively. FTST was correlated with both the HHS and TUG (r1 = ?0.522, r2 = 0.730, p < 0.01). SEM95 and MDC95 values of the ST (right) were 0.37 and 1.02, respectively. SEM95 and MDC95 values of the ST (left) were 0.55 and 1.52, respectively. Also, ST (right) was only correlated with TUG (r = ?0.654, p < 0.01). ST (right) were correlated with both the HHS and TUG (r1 = 0.503, r2 = ?0.806, p < 0.01). The degree of correlations was strong. Conclusion: The FTST and ST are valid and reliable performance tests in older adults with primary unilateral THA. © 2020 Elsevier Inc.en_US
dc.description.sponsorshipNone.en_US
dc.item-language.isoengen_US
dc.publisherElsevier Inc.en_US
dc.item-rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectConcurrent validity, five times sit to stand testen_US
dc.subjectTest-retest reliabilityen_US
dc.subjectTotal hip arthroplastyen_US
dc.titleThe test-retest reliability and concurrent validity of the five times sit to stand test and step test in older adults with total hip arthroplastyen_US
dc.item-typearticleen_US
dc.contributor.departmentMÜ, Köyceğiz Sağlık Hizmetleri Meslek Yüksekokulu, Sağlık Bakım Hizmetleri Bölümüen_US
dc.contributor.institutionauthorÖzden, Fatih
dc.identifier.doi10.1016/j.exger.2020.111143
dc.identifier.volume142en_US
dc.relation.journalExperimental Gerontologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster