A full-scale field study on mitigation of environmental ground vibrations by using open trenches

Thumbnail

Göster/Aç

Tam Metin / Full Text (12.46Mb)

Tarih

2021

Yazar

Toygar, Onur
Ülgen, Deniz

Üst veri

Tüm öğe kaydını göster

Künye

Toygar, O. and D. Ulgen. 2021. "A Full-Scale Field Study on Mitigation of Environmental Ground Vibrations by using Open Trenches." Building and Environment 203. doi:10.1016/j.buildenv.2021.108070. www.scopus.com.

Özet

Environmental ground vibrations induced by construction operations, machine foundations, vehicular and railway traffic may cause discomfort to the dwellers in their immediate vicinity and malfunctioning of sensitive equipment in nearby structures. Associated with technological development and rapid industrialization, undesired vibrations around the residential areas have increased. Hence, the isolation of those vibrations has become an important issue. Open trenches are mainly employed as wave barriers in mitigation of undesired vibrations. Recent studies have focused on the parameters affecting the vibration isolation performance of open and in-filled trenches. It is stated that screening effectiveness mainly depends on the type of the vibration source and geometric dimensions of open trenches along with the local site conditions. In the present study, a series of full-scale field experiments were conducted to identify the effects of governing parameters on efficiency. The amplitudes of ground vibrations, artificially generated on the site, were measured through highly sensitive accelerometers at different test configurations. It was concluded that the frequency of vibrations had more influence than the actual depth of the barrier on screening effectiveness. Better isolation can be achieved in a region close to the trench while the effectiveness decreases at great distances. In addition, the results were compared with those of recently reported in experimental studies

Kaynak

Building and Environment

Cilt

203

Bağlantı

https://doi.org/10.1016/j.buildenv.2021.108070
https://hdl.handle.net/20.500.12809/9389

Koleksiyonlar

  • İnşaat Mühendisliği Bölümü Koleksiyonu [68]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.