Exergy and thermoeconomic analyses of the diffusion absorption refrigeration system with various nanoparticles and their different ratios as work fluid

Thumbnail

Göster/Aç

Tam metin / Full text (2.876Mb)

Tarih

2022

Yazar

Yağız Gürbüz, Emine
Keçebaş, Ali
Sözen, Adnan

Üst veri

Tüm öğe kaydını göster

Künye

Gürbüz, E. Y., Keçebaş, A., & Sözen, A. (2022). Exergy and thermoeconomic analyses of the diffusion absorption refrigeration system with various nanoparticles and their different ratios as work fluid. Energy, 248, 123579.

Özet

The fact that diffusion absorption refrigeration (DAR) systems can also work with low power plants has increased the interest in these cooling systems again. The DAR systems are mostly analyzed using energy analysis. Although, energy analysis is not adequate itself, so exergy analysis is required. In this study, the effects of nanofluid use on the DAR system performance are investigated by performing exergy and thermoeconomic analyses. Some nanoparticles like MgOAl2O3, ZnOAl2O3 and TiO2 in various weight ratios are used in the DAR system. In experiments with different nanoparticles, the effect of utilizing hybrid nanoparticles on enhancing system performance is also evaluated. The highest exergy destruction rate occurs in the solution heat exchanger, although the lowest exergy destruction rate happens in the condenser. The highest exergy efficiency with 0.798 is found in the base fluid (25% NH3-H2O). Besides, it is clearly observed that exergy efficiency decreased in the DAR systems using nanofluids. Moreover, the economic analysis of the DAR system is added to the study in order to evaluate the relationship between the exergy destruction rate and initial investment costs. It is found that the DAR system with ZnOAl2O3 (2 wt%) is preferable compared to other DAR systems. (C)& nbsp;2022 Published by Elsevier Ltd.

Kaynak

ENERGY

Cilt

248

Bağlantı

https://doi.org/10.1016/j.energy.2022.123579
https://hdl.handle.net/20.500.12809/10021

Koleksiyonlar

  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu [104]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.