• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Muğla
  • Fakülteler
  • Mühendislik Fakültesi
  • İnşaat Mühendisliği Bölümü Koleksiyonu
  • Öğe Göster
  •   DSpace@Muğla
  • Fakülteler
  • Mühendislik Fakültesi
  • İnşaat Mühendisliği Bölümü Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Assessing vibration isolation performance of single and coupled wave barriers through field experiments

Thumbnail

Göster/Aç

Tam metin / Article (14.36Mb)

Tarih

2022

Yazar

Toygar, onur
Ülgen, Deniz
Fidan, Numan Burak

Üst veri

Tüm öğe kaydını göster

Künye

Toygar, O., D. Ulgen, and N. B. Fidan. 2022. "Assessing Vibration Isolation Performance of Single and Coupled Wave Barriers through Field Experiments." Construction and Building Materials 354. doi:10.1016/j.conbuildmat.2022.129156

Özet

Wave barriers have become a common practice in the mitigation of undesired ground vibrations when direct isolation of the source has not been applicable. Even though the vibration isolation performance of open and in-filled trenches has been scrutinized, only a limited number of experimental studies are available about stiff wave barriers such as piles and sheetpiles. The present study aimed at assessing not only the screening effectivenesses of single barriers such as open trench and sheetpile but also the coupled open trench-sheetpile barrier. 15 m long, 0.75 m wide, 3 m deep single open trench and 15 m long, 8 m deep sheetpile were investigated in full-scale vibration tests. The influences of excitation frequency, source-barrier distance and barrier type on the vibration isolation were examined. The efficacy of the single and coupled-wave barriers was quantitatively presented within a wide range of frequencies (10–80 Hz) based on field measurements using highly sensitive accelerometers and geophones. No vibration isolation was provided at the excitation frequency of 10 Hz, while all the wave barriers provided an appreciable amount of reduction in the amplitudes of the vibrations at other frequencies. In most of the test configurations, the open trench and the coupled-wave barrier exhibited similar isolation performance and outperformed the sheetpile. In cases the sheetpile has already been installed, the implementation of an open trench in front of the sheetpile may noticeably improve the screening effectiveness.

Kaynak

Construction and Building Materials

Cilt

354

Bağlantı

https://doi.org/10.1016/j.conbuildmat.2022.129156
https://hdl.handle.net/20.500.12809/10315

Koleksiyonlar

  • İnşaat Mühendisliği Bölümü Koleksiyonu [68]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.