• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace@Muğla
  • Fakülteler
  • Fen Fakültesi
  • İstatistik Bölümü Koleksiyonu
  • View Item
  •   DSpace@Muğla
  • Fakülteler
  • Fen Fakültesi
  • İstatistik Bölümü Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Validation of a blood gas device for ionized calcium analysis in Holstein cows

Thumbnail

View/Open

Tam metin / Article (3.441Mb)

Date

2023

Author

Deniz, Abdülkerim
Metin, Mert
Aksoy, Kemal
Pekmezci, Aytaç

Metadata

Show full item record

Citation

Deniz, A, Metin, M, Aksoy, K, Pekmezci, A. Validation of a blood gas device for ionized calcium analysis in Holstein cows. Vet Clin Pathol. 2023; 00: 1- 8. doi:10.1111/vcp.13233

Abstract

Background: Accurate analysis of ionized calcium (iCa) is critical for the detection of hypocalcemia or subclinical hypocalcemia. The Edan i15 Vet (EDAN) blood gas device has not been validated for iCa in dairy cows. Objectives: We aimed to validate the EDAN blood gas device against the Gem Premier 3000 (GEM) analyzer by measuring iCa concentrations and evaluating the ability of these measurements, compared with serum total calcium (TCa) concentrations, to diagnose subclinical hypocalcemia. Methods: iCa concentrations were measured with the EDAN and GEM devices, and serum TCa concentrations were measured with a wet biochemistry method with blood from 125 lactating Holstein cows between calving to day 27 postpartum. Results: Bland-Altman plots showed a mean and total bias of 0.05 and 0.24 mmol/L for the EDAN device, respectively. The intercept did not include zero, but the slope included 1.0 in the Passing-Bablok regression. The sensitivity and specificity (Se/Sp) of the EDAN device were 93/94%, 93/90%, 91/93%, and 85/95% for iCa cut-off values of <1.00, 1.05, 1.10, and 1.15 mmol/L, respectively, as determined with the GEM device. The Se/Sp were 57/82% and 72/80% for EDAN and 57/80% and 72/79% for GEM at serum TCa cut-off points <2.15 and <2.00 mmol/L, respectively. The average iCa concentrations analyzed with the GEM and EDAN devices were 1.04 ± 0.18 and 1.09 ± 0.17, respectively. Conclusions: The EDAN device did not have satisfactory agreement with GEM and could not be used interchangeably, but it had satisfactory Se/Sp to diagnose subclinical hypocalcemia compared with the GEM-derived iCa cut-off points. Serum TCa concentration cut-off values were not suitable for diagnosing subclinical hypocalcemia because of unsatisfactory Se/Sp compared with iCa concentrations analyzed by the GEM and EDAN devices. The iCa values analyzed using the EDAN and GEM devices were consistent with previously reported data.

Source

Veterinary Clinical Pathology

URI

https://doi.org/10.1111/vcp.13233
https://hdl.handle.net/20.500.12809/10593

Collections

  • İstatistik Bölümü Koleksiyonu [95]
  • PubMed İndeksli Yayınlar Koleksiyonu [2082]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Muğla

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Guide|| Instruction || Library || Muğla Sıtkı Koçman University || OAI-PMH ||

Muğla Sıtkı Koçman University, Muğla, Turkey
If you find any errors in content, please contact:

Creative Commons License
Muğla Sıtkı Koçman University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.