Umbilical Cord Diameter at the Junction of the Body Wall in the Newborn. Is It a Biomarker for Congenital Umbilical Hernia?
Özet
Introduction: The aim is to obtain normal newborn umbilical cord diameters for use it in the evaluation of congenital umbilical hernia. Materials and methods: The umbilical cord diameter (UCD) at the abdominal wall, maternal age, birth weight, gestational age at birth, birth height, head, chest and abdominal circumferences, and the time of measurement after birth was noted. Results: Mean +/- standard deviation and median (minimum-maximum) values of the UCD were 9.9 +/- 1.9 mm, 10.0 (5-16 mm), respectively. There was a significance for a positive low correlation between birth height and UCD (p = .039, r = .143). No other birth parameter had a significant correlation with UCD. The gender of the newborn (p = .95) and the type of delivery (p = .056) did not affect UCD. Conclusion: These data may be used in determining the normality of UCD, which could be helpful in the evaluation of umbilical hernias.
Kaynak
Fetal and Pediatric PathologyCilt
37Sayı
4Koleksiyonlar
İlgili Öğeler
Başlık, yazar, küratör ve konuya göre gösterilen ilgili öğeler.
-
Relation between serum PAPP-A level and umbilical cord thickness during first trimester of pregnancy
Duran, Muzeyyen; Kosus, Aydin; Kosus, Nermin; Turhan, Nilgun O. (Taylor & Francis Ltd, 2014)Purpose: To evaluate the relation between umbilical cord diameter versus pregnancy associated plasma protein-A (PAPP-A) level in first trimester women. Method: Cord diameter were measured and patients were divided into two ... -
Conservative vs Surgical Interventions for Umbilical Pilonidal Sinus: A Multicenter, Double-Blind, Prospective, Randomized Clinical Trial
Kaplan, Mehmet; Özcan, Önder; Kaplan, Fatma Çiğdem; Yalçın, Hüseyin Cahit; Salman, Bülent (Elsevier Science Inc, 2016)BACKGROUND: Umbilical pilonidal sinus (UPS) is one of the most neglected disorders, and there is still no clear consensus regarding optimal treatment of the disease. We therefore present our data from a prospective, ... -
Low pertussis antibody levels in maternal and umbilical cord blood samples in Turkey
Türkoğlu, Ebru; Sönmez, Cemile; Özer, Esra; Çoplu, Nilay; Kurugöl, Zafer (Turkish J Pediatrics, 2016)Pertussis continues to cause significant mortality and morbidity in many countries despite high vaccine coverage, especially among young infants. The aim of the study was to determine pertussis antibody levels in paired ...


















