• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace@Muğla
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
  •   DSpace@Muğla
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Reproducibility of the water-drinking test in patients with exfoliation syndrome and exfoliative glaucoma

Thumbnail

View/Open

Tam metin / Full text (246.4Kb)

Date

2016

Author

Özyol, Erhan
Özyol, Pelin
Karalezli, Aylin

Metadata

Show full item record

Abstract

PurposeTo evaluate the reproducibility of intraocular pressure (IOP) peaks and fluctuations detected during the water-drinking test (WDT) in patients with exfoliation syndrome (XFS) and exfoliative glaucoma (XFG). MethodsThis prospective study included 34 XFS and 30 XFG patients. Each patient was evaluated twice, with the two WDTs performed on a 30-day interval. We recorded IOP peak (highest IOP during the WDT) and IOP fluctuation (IOP peak minus IOP before the test). Bland-Altman analysis was applied to assess the agreement of IOP peaks and fluctuations between the two consecutive visits. We defined reproducible as within 4 mmHg for IOP peak and within 2 mmHg for IOP fluctuation. ResultsThere were no significant differences in IOP values, IOP peaks and IOP fluctuations between the two visits for both XFS and XFG patients (p>0.05, for all). The coefficient of repeatability for IOP peak was 2.5mmHg and 3.5mmHg in XFS and XFG patients respectively and for IOP fluctuation, it was 2.1mmHg and 2.2mmHg. None of the XFS or XFG patients had an IOP peak difference higher than 4mmHg. Intraocular pressure (IOP) fluctuation differences above 2.0mmHg were found in 8.8% of XFS patients and 16.6% of XFG patients. ConclusionsIntraocular pressure (IOP) peak and IOP fluctuation have a reproducibility, both in XFS and in XFG.

Source

Acta Ophthalmologica

Volume

94

Issue

8

URI

https://doi.org/10.1111/aos.13132
https://hdl.handle.net/20.500.12809/2271

Collections

  • Cerrahi Tıp Bilimleri Bölümü Koleksiyonu [543]
  • PubMed İndeksli Yayınlar Koleksiyonu [2082]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Muğla

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Guide|| Instruction || Library || Muğla Sıtkı Koçman University || OAI-PMH ||

Muğla Sıtkı Koçman University, Muğla, Turkey
If you find any errors in content, please contact:

Creative Commons License
Muğla Sıtkı Koçman University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.