Determination and interference studies of bismuth by tungsten trap hydride generation atomic absorption spectrometry

Date

2009

Author

Kula, Ibrahim
Arslan, Yasin
Bakirdere, Sugin
Titretir, Serap
Kenduezler, Erdal
Ataman, O. Yavuz

Metadata

Show full item record

Abstract

The determination of bismuth requires sufficiently sensitive procedures for detection at the mu g L-1 level or lower. W-coil was used for on-line trapping of volatile bismuth species using HGAAS (hydride generation atomic absorption spectrometry); atom trapping using a W-coil consists of three steps. Initially BiH3 gas is formed by hydride generation procedure. The analyte species in vapor form are transported through the W-coil trap held at 289 degrees C where trapping takes place. Following the preconcentration step, the W-coil is heated to 1348 degrees C; analyte species are released and transported to flame-heated quartz atom cell where the atomic signal is formed. In our study, interferences have been investigated in detail during Bi determination by hydride generation, both with and without trap in the same HGAAS system. Interferent/analyte (mass/mass) ratio was kept at 1, 10 and 100. Experiments were designed for carrier solutions having 1.0 M HNO3. Interferents such as Fe, Mn, Zn, Ni, Cu, As, Se. Cd, Pb, Au, Na, Mg, Ca, chloride, sulfate and phosphate were examined. The calibration plot for an 8.0 ml. sampling volume was linear between 0.10 mu g L-1 and 10.0 mu g L-1 of Bi. The detection limit (3 s/m) was 25 ng L-1. The enhancement factor for the characteristic concentration (C-o) was found to be 21 when compared with the regular system without trap, by using peak height values. The validation of the procedure was performed by the analysis of the certified water reference material and the result was found to be in good agreement with the certified values at the 95% confidence level. (C) 2009 Elsevier B.V. All rights reserved.

Source

Talanta

Volume

80

Issue

1

URI

https://doi.org/10.1016/j.talanta.2009.06.084
https://hdl.handle.net/20.500.12809/4719

Collections

  • PubMed İndeksli Yayınlar Koleksiyonu [2082]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Muğla

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Guide|| Instruction || Library || Muğla Sıtkı Koçman University || OAI-PMH ||

Muğla Sıtkı Koçman University, Muğla, Turkey
If you find any errors in content, please contact:

Creative Commons License
Muğla Sıtkı Koçman University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.