A novel analytical system involving hydride generation and gold-coated W-coil trapping atomic absorption spectrometry for selenium determination at ng l(-1) level

Tarih

2008

Yazar

Kula, I.
Arslan, Y.
Bakirdere, S.
Ataman, O. Y.

Üst veri

Tüm öğe kaydını göster

Özet

A novel analytical technique was developed where gaseous hydrogen selenide formed by sodium tetra hydrobora te reduction is transported to and trapped on a resistively heated gold-coated W-coil atom trap for in situ preconcentration. Gold coating on W-coil was prepared by using an organic solution of Au. The atom trap is held at 165 degrees C during the collection stage and is heated up to 675 degrees C for revolatilization; analyte species formed are transported to an externally heated quartz T-tube where the atornization takes place and the transient signal is obtained. The carrier gas consisted of 112.5 ml min' At with 75 ml min(-1) H-2 during the collection step and 112.5 ml min(-1) At with 450 ml min(-1) H-2 in the revolatilization step. The half width of the transient signal obtained is less than 0.5 s. The RSD for the measurements was found to be 3.9% (n = 11) for 0.10 mu g l(-1) Se using peak height measurements. The calibration plot for 27.0 ml of sample collected in 4.0 min using a flow rate of 6.75 ml min(-1) was linear between 0.13 and 2.0 mu g l(-1) of Se. The limit of detection (3 s) is 39 ng l(-1). The enhancement factor for the characteristic concentration (Co) was found to be 20.1 when compared to conventional hydride generation atomic absorption spectrometry system without trap. In order to check the accuracy of the method. standard reference material, natural water NIST 1640 was employed; the result was found to be in good agreement with the certified value at the 95% confidence level. (c) 2008 Elsevier B.V. All rights reserved.

Kaynak

Spectrochimica Acta Part B-Atomic Spectroscopy

Cilt

63

Sayı

8

Bağlantı

https://doi.org/10.1016/j.sab.2008.03.020
https://hdl.handle.net/20.500.12809/4936

Koleksiyonlar

  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.