Basit öğe kaydını göster

dc.contributor.authorAbdullin, S.
dc.contributor.authorAbramov, V.
dc.contributor.authorAcharya, B.
dc.contributor.authorAdams, M.
dc.contributor.authorAkchurin, N.
dc.contributor.authorAkgun, U.
dc.contributor.authorZeyrek, M.
dc.contributor.authorCankoçak, Kerem
dc.date.accessioned2020-11-20T16:36:45Z
dc.date.available2020-11-20T16:36:45Z
dc.date.issued2008
dc.identifier.issn1434-6044
dc.identifier.issn1434-6052
dc.identifier.urihttps://doi.org/10.1140/epjc/s10052-007-0459-4
dc.identifier.urihttps://hdl.handle.net/20.500.12809/5001
dc.descriptionPetrosyan, Artem/0000-0003-2166-7894; Piperov, Stefan/0000-0002-9266-7819; Gumus, Kazim/0000-0002-1450-6868; Ozkorucuklu, Suat/0000-0001-5153-9266; Kuleshov, Sergey V/0000-0002-3065-326X; Gulmez, Erhan/0000-0002-6353-518X; Bodek, Arie/0000-0003-0409-0341; TOPAKSU, Aysel KAYIS/0000-0001-5819-6913; Cankocak, Kerem/0000-0002-3829-3481; Babich, Kanstantsin S./0000-0002-4493-0571; Yazgan, Efe/0000-0001-5732-7950; AYDIN, Sezgin/0000-0001-5380-1512; Baarmand, Marc/0000-0002-9792-8619; Lychkovskaya, Natalia/0000-0001-5084-9019; Mondal, Naba/0000-0002-4098-8063; Sogut, Kenan/0000-0002-9682-2855; Uliyanov, Alexey/0000-0001-6935-8949en_US
dc.descriptionWOS: 000251382800015en_US
dc.description.abstractWe report on the test beam results and calibration methods using high energy electrons, pions and muons with the CMS forward calorimeter (HF). The HF calorimeter covers a large pseudorapidity region (3 <= vertical bar eta vertical bar <= 5), and is essential for a large number of physics channels with missing transverse energy. It is also expected to play a prominent role in the measurement of forward tagging jets in weak boson fusion channels in Higgs production. The HF calorimeter is based on steel absorber with embedded fused-silica-core optical fibers where Cherenkov radiation forms the basis of signal generation. Thus, the detector is essentially sensitive only to the electromagnetic shower core and is highly non-compensating (e/h approximate to 5). This feature is also manifest in narrow and relatively short showers compared to similar calorimeters based on ionization. The choice of fused-silica optical fibers as active material is dictated by its exceptional radiation hardness. The electromagnetic energy resolution is dominated by photoelectron statistics and can be expressed in the customary form as a/root E circle plus b. The stochastic term a is 198% and the constant term b is 9%. The hadronic energy resolution is largely determined by the fluctuations in the neutral pion production in showers, and when it is expressed as in the electromagnetic case, a = 280% and b = 11%.en_US
dc.item-language.isoengen_US
dc.publisherSpringeren_US
dc.item-rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleDesign, performance, and calibration of CMS forward calorimeter wedgesen_US
dc.item-typearticleen_US
dc.contributor.departmentMÜ, Fen Fakültesi, Fizik Bölümüen_US
dc.contributor.institutionauthorCankoçak, Kerem
dc.identifier.doi10.1140/epjc/s10052-007-0459-4
dc.identifier.volume53en_US
dc.identifier.issue1en_US
dc.identifier.startpage139en_US
dc.identifier.endpage166en_US
dc.relation.journalEuropean Physical Journal Cen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster