• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Muğla
  • Fakülteler
  • Teknoloji Fakültesi
  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu
  • Öğe Göster
  •   DSpace@Muğla
  • Fakülteler
  • Teknoloji Fakültesi
  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Thermodynamic performance evaluation of a heat pump system with textile based solar air heater for heating process

Thumbnail

Göster/Aç

Tam metin / Full Text (4.598Mb)

Tarih

2021

Yazar

Ural, Tolga
Keçebaş, Ali
Güler, Onur Vahip

Üst veri

Tüm öğe kaydını göster

Künye

Ural, T., A. Keçebaş, and O. V. Güler. 2021. "Thermodynamic Performance Evaluation of a Heat Pump System with Textile Based Solar Air Heater for Heating Process." Applied Thermal Engineering 191. doi:10.1016/j.applthermaleng.2021.116905.

Özet

In this study, a newly system is designed and tested which integrates air-to-water heat pump and solar air collector having fabric absorber for the shortcoming of frost depositing on the evaporator in heating condition. Thus, it can achieve synchronous and heat exchange in one integrated system between R410A, gaseous and liquid heat source. In addition, the system performance is evaluated in comparison with those of the standard heat pump and the flat-plate solar air collector assisted heat pump under the same climatic conditions. In this respect, experimental tests are performed for winter season and the thermodynamic inefficiencies’ changes are monitored by real-time exergy analysis under climate conditions of the Muğla province/Turkey. This approximation allows the designer and the manufacturer to see the progress. The results of the study indicate that the textile based solar air collector assisted heat pump shows superior performance with 5.11 COP and 56% exergy efficiency when compared to the other two heat pumps. The equipment with the highest exergy destruction is determined as evaporator. In low temperatures, the problem of frost depositing on the evaporator is solved faster with the use of solar air collector. With the use of a textile-based solar air collector on heat pump, the electrical consumption of the compressor is reduced by 8.3%. Consequently, the proposed system clearly demonstrated its applicability as an independent and reliable system for the building heating process due to its benefits like energy saving, protection against environmental conditions and evaporator’ anti-frost deposit behavior.

Kaynak

Applied Thermal Engineering

Cilt

191

Bağlantı

https://doi.org/10.1016/j.applthermaleng.2021.116905
https://hdl.handle.net/20.500.12809/9174

Koleksiyonlar

  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu [104]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.