• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Muğla
  • Fakülteler
  • Tıp Fakültesi
  • Dahili Tıp Bilimleri Bölümü Koleksiyonu
  • Öğe Göster
  •   DSpace@Muğla
  • Fakülteler
  • Tıp Fakültesi
  • Dahili Tıp Bilimleri Bölümü Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

The Relationship Between Posterior Communicating Artery Formation and Vertebral Artery Flow Parameters

Thumbnail

Göster/Aç

Tam Metin / Full Text (967.9Kb)

Tarih

2021

Yazar

Yeniçeri, İbrahim Önder
Bek, Vedat Semai
Çullu, Neşat
Kutlu, Gülnihal

Üst veri

Tüm öğe kaydını göster

Künye

Yeniçeri İÖ, Bek VS, Çullu N, Kutlu G. The Relationship Between Posterior Communicating Artery Formation and Vertebral Artery Flow Parameters. Journal of Diagnostic Medical Sonography. April 2021. doi:10.1177/87564793211005952

Özet

Objectives: It is important to know the range of normal vertebral artery (VA) flow volume. Diminished VA flow volume is associated with vertebrobasilar insufficiency. The study aim was to investigate the relationship between the posterior communicating artery (PCoA) calibration and the VA flow parameters, in patients with no underlying cerebrovascular disease, below 50 years of age. Materials and Methods: The study population consisted of 102 cases below 50 years of age. The basilar artery (BA), internal carotid artery (ICA), and the PCoA calibrations were measured with magnetic resonance angiography. The VA flow parameters (maximum systolic velocity, end-diastolic velocity, mean velocity, VA flow volume, and VA calibration) were measured with duplex sonography. Results: There was no statistically significant difference between these two imaging groups, in terms of VA Vmax, VA flow volumes, VA calibrations, and BA calibrations. However, the mean right ICA and mean left ICA calibrations were significantly higher in group 2 than group 1 (P <.01). There was no significant correlation between mean PCoA calibration and mean Vmax, mean calibration, and the total flow volume of vertebral arteries. Conclusion: The findings indicate that the VA flow rate may be relatively maintained, regardless of PCoA measurements in this study.

Kaynak

Journal of Diagnostic Medical Sonography

Bağlantı

https://doi.org/10.1177/87564793211005952
https://hdl.handle.net/20.500.12809/9201

Koleksiyonlar

  • Dahili Tıp Bilimleri Bölümü Koleksiyonu [691]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.