Basit öğe kaydını göster

dc.contributor.authorKılınç, Rabia Mihriban
dc.contributor.authorAçan, Ahmet Emrah
dc.contributor.authorTürk, Gamze
dc.contributor.authorKılınç, Cem Yalın
dc.contributor.authorYeniçeri, İbrahim Önder
dc.date.accessioned2021-06-08T11:20:19Z
dc.date.available2021-06-08T11:20:19Z
dc.date.issued2021en_US
dc.identifier.citationKılınc RM, Açan AE, Türk G, Kılınç CY, Yeniçeri İÖ. Evaluation of femoral head bone quality by Hounsfield units: a comparison with dual-energy X-ray absorptiometry. Acta Radiol. 2021 Jun 2:2841851211021035. doi: 10.1177/02841851211021035. Epub ahead of print. PMID: 34078124.en_US
dc.identifier.urihttps://doi.org/10.1177/02841851211021035
dc.identifier.urihttps://hdl.handle.net/20.500.12809/9299
dc.description.abstractBackground: Osteoporosis is associated with decreases in bone mineral density (BMD) and is diagnosed using dual-energy X-ray absorptiometry (DXA). Computed tomography (CT), performed in routine practice, can also be used to evaluate bone quality without additional cost. Purpose: To determine whether Hounsfield units (HU), a standardized CT attenuation coefficient, measured from the femoral head correlated with DXA-measured BMD. Material and methods: We evaluated 82 patients (14 men, 68 women; mean age, 67 years) undergoing femoral DXA and CT (non-enhanced abdominopelvic and hip scans) with 130 kV to determine whether HU correlated with T-scores. HU were measured by two radiologists using the largest spherical region of interest including the medullary bone of the femoral head from the junction point of the most caudal section of the femoral head with the femoral neck in 5-mm axial sections. The correlations of both sides' HU values with their ages and DXA femur T-score were evaluated. Results: HU values obtained from both femoral heads showed significant variation between the osteoporotic and non-osteoporotic groups (both P = 0.000) and strongly correlated with each other and DXA femur T-scores (left r = 0.75, right r = 0.73, respectively). In ROC curve analysis, predictive power of left HU values in identifying patients with osteoporotic femur DXA T-score was 0.905, and for right HU values it was 0.924. Osteoporosis cutoff values were 198 HU and 204 HU for the left and right hips, respectively. Conclusions: HU obtained from CT performed in routine practice correlated with the DXA scores, thus providing an alternative method to determine regional bone quality without additional cost. This may be useful when choosing a fixation method, especially in trauma cases with already-performed abdominopelvic or pelvic CT in emergency services.en_US
dc.item-language.isoengen_US
dc.publisherSAGE Publications Inc.en_US
dc.relation.isversionof10.1177/02841851211021035en_US
dc.item-rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectHounsfield uniten_US
dc.subjectOsteoporosisen_US
dc.subjectT-scoresen_US
dc.subjectBone qualityen_US
dc.subjectDual-energy X-ray absorptiometryen_US
dc.titleEvaluation of femoral head bone quality by Hounsfield units: a comparison with dual-energy X-ray absorptiometryen_US
dc.item-typearticleen_US
dc.contributor.departmentMÜ, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümüen_US
dc.contributor.authorID0000-0002-6845-5496en_US
dc.contributor.institutionauthorKılınç, Rabia Mihriban
dc.contributor.institutionauthorKılınç, Cem Yalın
dc.contributor.institutionauthorYeniçeri, İbrahim Önder
dc.relation.journalActa Radiologicaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster