Trombe Wall Application with Heat Storage Tank

Tarih

2019

Yazar

Topcuoglu, Kivanc

Üst veri

Tüm öğe kaydını göster

Özet

In this study, an investigation was made of the performance of a Trombe wall of classical structure used together with a heat store. Most Trombe walls are able to supply the heating needs of a space to which they are connected without the need for extra heating at times when the sun is shining. However, the heat obtained from the Trombe wall can be in excess of needs at such times, and measures must be taken to provide ventilation to the heated space. It is thought that the heat energy can be used more efficiently and productively by storing the excess heat outside the building and using it inside the building when there is no sunlight. To this purpose, a tank full of water and marble was built as a heat store as an alternative to the general Trombe wall design, and an attempt was made to minimise heat losses by burying it in the ground. It was concluded that in place of a traditional Trombe wall system using a massive wall heat store, a heat store could be constructed in a different position and with different materials. The Trombe wall system which was developed and tested met up to 30% of the energy needed for heating and cooling the building, and reduced the architectural and static disadvantages of Trombe wall systems. As a result of the study, it was seen that where a standard reinforced concrete wall could supply heat to the inside for 7 hours and 12 minutes, the figure for a wall made of paraffin wax was 8 hours and 55 minutes. In the same study, the heat storage thickness of a reinforced concrete wall was calculated as 20 cm, while that of a paraffin wax wall was calculated as 5 cm.

Kaynak

Civil Engineering Journal-Tehran

Cilt

5

Sayı

7

Bağlantı

https://doi.org/10.28991/cej-2019-03091346
https://hdl.handle.net/20.500.12809/966

Koleksiyonlar

  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.