Basit öğe kaydını göster

dc.contributor.authorToygar, onur
dc.contributor.authorÜlgen, Deniz
dc.contributor.authorFidan, Numan Burak
dc.date.accessioned2022-10-04T10:36:19Z
dc.date.available2022-10-04T10:36:19Z
dc.date.issued2022en_US
dc.identifier.citationToygar, O., D. Ulgen, and N. B. Fidan. 2022. "Assessing Vibration Isolation Performance of Single and Coupled Wave Barriers through Field Experiments." Construction and Building Materials 354. doi:10.1016/j.conbuildmat.2022.129156en_US
dc.identifier.issn09500618
dc.identifier.urihttps://doi.org/10.1016/j.conbuildmat.2022.129156
dc.identifier.urihttps://hdl.handle.net/20.500.12809/10315
dc.description.abstractWave barriers have become a common practice in the mitigation of undesired ground vibrations when direct isolation of the source has not been applicable. Even though the vibration isolation performance of open and in-filled trenches has been scrutinized, only a limited number of experimental studies are available about stiff wave barriers such as piles and sheetpiles. The present study aimed at assessing not only the screening effectivenesses of single barriers such as open trench and sheetpile but also the coupled open trench-sheetpile barrier. 15 m long, 0.75 m wide, 3 m deep single open trench and 15 m long, 8 m deep sheetpile were investigated in full-scale vibration tests. The influences of excitation frequency, source-barrier distance and barrier type on the vibration isolation were examined. The efficacy of the single and coupled-wave barriers was quantitatively presented within a wide range of frequencies (10–80 Hz) based on field measurements using highly sensitive accelerometers and geophones. No vibration isolation was provided at the excitation frequency of 10 Hz, while all the wave barriers provided an appreciable amount of reduction in the amplitudes of the vibrations at other frequencies. In most of the test configurations, the open trench and the coupled-wave barrier exhibited similar isolation performance and outperformed the sheetpile. In cases the sheetpile has already been installed, the implementation of an open trench in front of the sheetpile may noticeably improve the screening effectiveness.en_US
dc.item-language.isoengen_US
dc.publisherElsevier Ltden_US
dc.relation.isversionof10.1016/j.conbuildmat.2022.129156en_US
dc.item-rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGround-borne vibrationen_US
dc.subjectScreening effectivenessen_US
dc.subjectCoupled-wave barrieren_US
dc.subjectOpen trenchen_US
dc.subjectSheetpileen_US
dc.subjectField measurementen_US
dc.titleAssessing vibration isolation performance of single and coupled wave barriers through field experimentsen_US
dc.item-typearticleen_US
dc.contributor.departmentMÜ, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.contributor.authorID0000-0003-2366-3993en_US
dc.contributor.institutionauthorToygar, Onur
dc.contributor.institutionauthorÜlgen, Deniz
dc.contributor.institutionauthorFidan, Numan Burak
dc.identifier.volume354en_US
dc.relation.journalConstruction and Building Materialsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US