dc.contributor.author | Şimşek, Cem | |
dc.contributor.author | Kaya, Cansu | |
dc.contributor.author | Karalezli, Aylin | |
dc.date.accessioned | 2023-01-02T07:50:11Z | |
dc.date.available | 2023-01-02T07:50:11Z | |
dc.date.issued | 2022 | en_US |
dc.identifier.citation | Şimşek C, Kaya C, Karalezli A. Evaluation of Corneal Alterations After Short-Term Silicone Hydrogel Contact Lens Use by Confocal Microscopy. Turk J Ophthalmol. 2022 Dec 28;52(6):386-393. doi: 10.4274/tjo.galenos.2021.27163. PMID: 36578196. | en_US |
dc.identifier.issn | 2147-2661 / 2149-8709 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12809/10470 | |
dc.description.abstract | Objectives: To evaluate the corneal subbasal nerve morphology, corneal sensitivity, and anterior segment alterations in short-term silicone hydrogel contact lens (SiHCL) users by confocal microscopy.
Materials and methods: The study included 25 right eyes of 25 male volunteers aged 25-30 years who had never used SiHCLs before. ocular surface disease index (OSDI), tear break-up time, Schirmer test, tear meniscus area, strip meniscometry tube, corneal sensitivity, and corneal subbasal nerve morphology were evaluated before and after 1 month of CL use.
Results: OSDI was 10.6±1.1 before CL use and 17.2±1.2 after 1 month of CL use (p<0.01). Schirmer test distance was 16.3±2.3 mm before and 14.3±1.9 mm after 1 month of CL use (p>0.05). Tear film break-up time was 7.1±0.4 s before and 6.2±0.3 s after CL use (p>0.05). The tear meniscus area was 0.026±0.002 mm2 before and 0.024±0.001 mm2 after 1 month of CL use (p>0.05). Strip meniscometry tube results were 5.4±0.9 mm before and 4.9±0.8 mm after 1 month of CL use (p>0.05). Corneal sensitivity values were 3.2±0.4 mm before and 2.95±0.3 mm after 1 month of CL use (p>0.05). Dendritic cell density evaluated by confocal microscopy was 14.84±3.1 cells/mm2 before and 32.57±4.2 cells/mm2 after 1 month of CL use (p<0.01). Subbasal nerve tortuosity was 0.92±0.2 before and 1.03±0.2 after 1 month of CL use (p>0.05). Subbasal nerve density was measured as 4726±310 pixels/frame before and 4570±272 pixels/frame after 1 month of CL use (p>0.05).
Conclusion: After a month of SiHCL use, no significant changes were observed in tear secretion, corneal sensitivity, tear meniscus volume, subbasal corneal nerve density, reflectivity, or tortuosity, while a significant increase was found in OSDI and dendritic cell density. | en_US |
dc.item-language.iso | eng | en_US |
dc.publisher | Galenos Publishing House | en_US |
dc.relation.isversionof | 10.4274/tjo.galenos.2021.27163. | en_US |
dc.item-rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Confocal microscope | en_US |
dc.subject | Contact lens | en_US |
dc.subject | Corneal sensitivity | en_US |
dc.subject | Subbasal cell density | en_US |
dc.subject | Ocular surface disease index | en_US |
dc.title | Evaluation of Corneal Alterations After Short-Term Silicone Hydrogel Contact Lens Use by Confocal Microscopy | en_US |
dc.item-type | article | en_US |
dc.contributor.department | MÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü | en_US |
dc.contributor.authorID | 0000-0001-8003-745X | en_US |
dc.contributor.authorID | 0000-0002-2230-3008 | en_US |
dc.contributor.authorID | 0000-0003-1316-4656 | en_US |
dc.contributor.institutionauthor | Şimşek, Cem | |
dc.contributor.institutionauthor | Kaya, Cansu | |
dc.contributor.institutionauthor | Karalezli, Aylin | |
dc.identifier.volume | 52 | en_US |
dc.identifier.issue | 6 | en_US |
dc.identifier.startpage | 386 | en_US |
dc.identifier.endpage | 393 | en_US |
dc.relation.journal | Turkish Journal of Ophthalmology | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |