dc.date.issued2022en_US
dc.identifier.citationSimsek M, Oral Y, Erogul O, Sabaner MC, Simsek C, Yorukoglu S. Comparison of the results of four different refraction measurement devices in children with retinoscopy. Rom J Ophthalmol. 2022 Oct-Dec;66(4):337-343. doi: 10.22336/rjo.2022.60. PMID: 36589324; PMCID: PMC9773113.en_US
dc.identifier.issn2501-2533  / 2457 – 4325
dc.identifier.urihttps://hdl.handle.net/20.500.12809/10480
dc.description.abstractPurpose: The purpose of this study was to compare the results of 4 different autorefractometer devices with the results of retinoscopy in children. Methods: A total of 120 eyes of 60 patients aged between 6 and 18, who applied to Afyonkarahisar Health Sciences University unit of Pediatric Ophthalmology, were included in the study. Refraction with Plusoptix A09 (photoscreener) without cycloplegia was the first to be measured. Spherical and cylindrical values were recorded. Then, half an hour after the patients were instilled 2 drops of cyclopentolate with an interval of 5 minutes, dilated retinoscopy was performed, and spherical and cylindrical values were recorded. Autorefractometer measurements with cycloplegia were performed with Canon RK-F1 autorefractometer, Nidek Tonoref III and Retinomax K-Plus 3, and spherical and cylindrical values were recorded. Results: The mean age of the patients was 11.02 ± 2.1. The mean spherical equivalents were Canon RKF1 autorefractometer +0.045 ± 2.49, Nidek TonoRef III +0.023 ± 2.48, Retinomax K-Plus 3 +0.078 ± 1.42, Plusoptix A09 -0.119 ± 2.20, retinoscopy +0.124 ± 2.65. Moreover, the mean cylindrical values were Canon RK-F1 autorefractometer -0.893 ± 0.69, Nidek TonoRef III -0.927 ± 0.72, Retinomax K-Plus 3 -0.888 ± 0.73, Plusoptix A09 -0.883 ± 0.719, retinoscopy -0.923 ± 0.71. The statistical values compared with retinoscopy; Canon RKF1 spherical equivalent (p=0.376), cylindrical (p=0.515), Nidek TonoRef III spherical equivalent (p=0.485), cylindrical (p=0.198), Retinomax K-Plus 3 spherical equivalent (p=0.141), cylindrical (p=0.058), Plusoptix A09 spherical equivalent (p=0.085) and cylindrical (p=0.086) values were not different. Conclusions: In spherical and cylindrical refractive error detection, all 4 devices showed reasonable and consistent results compared to retinoscopy.en_US
dc.item-language.isoengen_US
dc.publisherPMCen_US
dc.relation.isversionof10.22336/rjo.2022.60en_US
dc.item-rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectRefractionen_US
dc.subjectRetinoscopyen_US
dc.subjectAmblyopiaen_US
dc.subjectSpherical equivalenten_US
dc.subjectAutorefractometeren_US
dc.titleComparison of the results of four different refraction measurement devices in children with retinoscopyen_US
dc.item-typearticleen_US
dc.contributor.departmentMÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.contributor.authorID0000-0002-9335-8049en_US
dc.contributor.authorID0000-0002-7037-5233en_US
dc.contributor.institutionauthorŞimşek, Merve
dc.contributor.institutionauthorŞimşek, Hüseyin Cem
dc.identifier.volume66en_US
dc.identifier.issue4en_US
dc.identifier.startpage337en_US
dc.identifier.endpage343en_US
dc.relation.journalRomanian Journal of Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US