Thermodynamic evaluation of a waste gas-fired steam power plant in an iron and steel facility using enhanced exergy analysis

Thumbnail

Göster/Aç

Tam metin / Full text (548.0Kb)

Tarih

2019

Yazar

Yılmaz, Kadir
Kayfeci, Muhammet
Kecebaş, Ali
Article has an altmetric score of 1

See more details

Posted by 1 X users
37 readers on Mendeley

Üst veri

Tüm öğe kaydını göster

Özet

Since the industrial revolution to nowadays, many waste gases have been produced in iron-steel facilities. These gases increased the amount of energy consumption and risky by CO2 emissions. For these reasons, the useful waste gases, energy saving and decreased emissions technology are made. In this study, a collection of real operating data has been performed in an existing steam power plant using the useful waste gas that has occurred in iron and steel production facilities according to their nature, traditional and enhanced exergy analyses of it. The thermodynamic performance of the system is evaluated by improvement potential of the system components and by the interaction between the components. Useful waste gases produced in the facility consist of blast furnace gas, coke oven gas and converter gas. These gases are used for boosting the pressure and temperature of the circulation water by means of the heat of the exhaust gas produced by burning them at the steam-powered Rankine cycle's boiler and its subcomponents. The results of the study showed that the traditional and the enhanced exergy efficiencies of the system are respectively 60.7% and 83.7%. Potential improvement of the system and the interaction between the components are determined as 24.8% (low) and 74.5% (high). System components with improvement priority are condenser; combustion chamber, turbine, first super-heater and economizer at the traditional exergy analysis; whereas a combustion chamber, turbine, first superheater, economizer and second super-heater at the enhanced exergy analysis. Thus, as a similar result to those for all conversion thermal systems, combustion chamber is a component that always needs to be improved. (C) 2018 Elsevier Ltd. All rights reserved.

Kaynak

Energy

Cilt

169

Bağlantı

https://doi.org/10.1016/j.energy.2018.12.007
https://hdl.handle.net/20.500.12809/1093

Koleksiyonlar

  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu [104]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.