dc.contributor.author | Vyhnanovsky, Jaromir | |
dc.contributor.author | Yıldız, Dilek | |
dc.contributor.author | Musil, Stanislav | |
dc.date.accessioned | 2020-11-20T14:42:52Z | |
dc.date.available | 2020-11-20T14:42:52Z | |
dc.date.issued | 2019 | |
dc.identifier.isbn | 978-80-7444-068-7 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12809/1121 | |
dc.description | 15th International Students Conference on Modern Analytical Chemistry - SEP 19-20, 2019 - Prague, CZECH REPUBLIC | en_US |
dc.description | WOS: 000576787700042 | en_US |
dc.description.abstract | Conditions of photochemical vapor generation of bismuth were optimized in a flow-injection system with a standard mercury low-pressure tube lamp and a coiled reactor. A high-resolution continuum source atomic absorption spectrometer was used as a detector that was equipped with a miniature diffusion flame as an atomizer. The influence of flow rate of a carrier gas, irradiation time and composition of a reaction medium was investigated. Combination of 40% (v/v) acetic acid with 1.25% (v/v) formic acid was found optimal. Subsequently, the use of various metals as sensitizers was studied to achieve maximum generation efficiency. Except the already published positive effect of Fe2+, three new sensitizers were found, with the enhancement effect in the following order: Cu2+ < Cd2+ << Co2+. Interference from nitric acid which is commonly used for digestion of real samples was investigated. The limit of detection achieved with the optimal conditions was 5.9 mu g L-1. | en_US |
dc.description.sponsorship | European Chem Soc, Div Analyt Chem, ECOM, Thermofisher, Fisher Sci, Lach Ner, Bruker Optik Instruments, 2Theta, Zentiva, Charles Univ, Fac Sci | en_US |
dc.description.sponsorship | Czech Science FoundationGrant Agency of the Czech Republic [17-04329S, 19-17604Y]; Czech Academy of SciencesCzech Academy of Sciences [RVO: 68081715]; Charles University [SVV260440] | en_US |
dc.description.sponsorship | The support of the Czech Science Foundation (Project No. 17-04329S and 19-17604Y), Czech Academy of Sciences (Institutional support RVO: 68081715) and Charles University (project SVV260440) is gratefully acknowledged. | en_US |
dc.item-language.iso | eng | en_US |
dc.publisher | Charles Univ, Fac Science | en_US |
dc.item-rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Bismuth | en_US |
dc.subject | High-Resolution Continuum Source Atomic Absorption Spectrometry | en_US |
dc.subject | Photochemical Vapor Generation | en_US |
dc.subject | UV-Radiation | en_US |
dc.title | Effect of metal sensitizers on photochemical vapor generation of bismuth for analytical atomic spectrometry | en_US |
dc.item-type | conferenceObject | en_US |
dc.contributor.department | MÜ, Rektörlük, Çevre Sorunları Araştırma Ve Uygulama Merkezi Müdürlüğü | en_US |
dc.contributor.institutionauthor | Yıldız, Dilek | |
dc.identifier.startpage | 257 | en_US |
dc.identifier.endpage | 262 | en_US |
dc.relation.journal | Proceedings of the 15Th International Students Conference Modern Analytical Chemistry | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |