dc.contributor.author | Özyol, Erhan | |
dc.contributor.author | Özyol, Pelin | |
dc.date.accessioned | 2020-11-20T14:52:43Z | |
dc.date.available | 2020-11-20T14:52:43Z | |
dc.date.issued | 2017 | |
dc.identifier.issn | 0301-4738 | |
dc.identifier.issn | 1998-3689 | |
dc.identifier.uri | https://doi.org/10.4103/ijo.IJO_618_16 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12809/1938 | |
dc.description | WOS: 000404739900007 | en_US |
dc.description | PubMed ID: 28643709 | en_US |
dc.description.abstract | Purpose: The purpose of this study was to compare the central corneal thickness (CCT) measurements of four noncontact devices in healthy eyes. Materials and Methods: In a sample of 45 healthy controls, CCT was measured using an optical biometer (IOLMaster 700) based on swept-source optical coherence tomography (SS-OCT), high-resolution rotating Scheimpflug camera system (Pentacam HR), spectral-domain OCT (SD-OCT) device with an anterior segment module (Spectralis), and noncontact pachymetry (NCP) device (Topcon TRK-2P). Agreement among the devices was analyzed using mean differences (i. e., bias) and Bland-Altman analysis with 95% limits of agreement (LoA). Results: Mean CCT measurements were 537.5 +/- 47.5 mu m for SS-OCT optical biometer, 532.3 +/- 43.8 mu m for Scheimpflug system, 521.3 +/- 44.7 mu m for SD-OCT device, and 518.0 +/- 43.1 mu m for NCP (P < 0.001). The SD-OCT device and NCP showed the closest agreement, with a bias of 2.6 mu m (95% LoA, -3.6-8.8 mu m), whereas the SS-OCT optical biometer and NCP showed the least agreement, with a bias of 18.7 mu m (95% LoA, -2.1-39.5 mu m). Bias was 16.1 mu m (95% LoA, -3.1-35.3 mu m) for SS-OCT optical biometer and SD-OCT, 5.1 mu m (95% LoA, -6.8-17.0 mu m) for SS-OCT optical biometer and Scheimpflug system, 10.9 mu m (95% LoA, -15.1-36.9 mu m) for SD-OCT device and Scheimpflug system, and 13.6 mu m (95% LoA, -5-32.2 mu m) for Scheimpflug system and NCP. Conclusions: SS-OCT optical biometer overestimates CCT measurements compared to Scheimpflug system, SD-OCT device, and NCP. Given mean differences and range variations in CCT measurements between devices, SS-OCT optical biometer and Scheimpflug system are interchangeable as are SD-OCT and NCP. | en_US |
dc.item-language.iso | eng | en_US |
dc.publisher | Medknow Publications & Media Pvt Ltd | en_US |
dc.item-rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Anterior Segment Optical Coherence Tomography | en_US |
dc.subject | Central Corneal Thickness | en_US |
dc.subject | Noncontact Pachymetry | en_US |
dc.subject | Scheimpflug Analysis System | en_US |
dc.subject | Swept-Source Optical Biometer | en_US |
dc.title | Comparison of central corneal thickness with four noncontact devices: An agreement analysis of swept-source technology | en_US |
dc.item-type | article | en_US |
dc.contributor.department | MÜ, Eğitim ve Araştırma Hastanesi | en_US |
dc.contributor.institutionauthor | Özyol, Erhan | |
dc.contributor.institutionauthor | Özyol, Pelin | |
dc.identifier.doi | 10.4103/ijo.IJO_618_16 | |
dc.identifier.volume | 65 | en_US |
dc.identifier.issue | 6 | en_US |
dc.identifier.startpage | 461 | en_US |
dc.identifier.endpage | 465 | en_US |
dc.relation.journal | Indian Journal of Ophthalmology | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |