Basit öğe kaydını göster

dc.contributor.authorKarakaya, Ilkim Citak
dc.contributor.authorKarakaya, Mehmet Gurhan
dc.contributor.authorErgun, Esra
dc.contributor.authorElmali, Sedanur
dc.contributor.authorFirat, Tuzun
dc.date.accessioned2020-11-20T16:18:39Z
dc.date.available2020-11-20T16:18:39Z
dc.date.issued2014
dc.identifier.issn1053-8127
dc.identifier.issn1878-6324
dc.identifier.urihttps://doi.org/10.3233/BMR-130436
dc.identifier.urihttps://hdl.handle.net/20.500.12809/3613
dc.descriptionKarakaya, Mehmet Gurhan/0000-0002-2395-649Xen_US
dc.descriptionWOS: 000336458300013en_US
dc.descriptionPubMed ID: 24254493en_US
dc.description.abstractBACKGROUND: Pulse frequency is one of the key determinants of analgesic outcomes by transcutaneous electrical nerve stimulation (TENS). However, optimal settings remain unclear. OBJECTIVE: To compare the effects of different frequencies of TENS, on pressure pain threshold and tolerance. METHODS: Currents with pulse duration of 110 mu s, and pulse frequencies of 60 pps or 150 pps were applied on the volar aspects of the dominant forearms of 20 healthy volunteers, on two consecutive days, in a randomized order. Threshold and tolerance were measured at the beginning, after the 15th and 30th minutes of the applications, and 30 minutes after the applications. RESULTS: Pressure pain threshold and tolerance values were higher at the 150 pps frequency, at all measurement times (p < 0.05). However, no frequencyXtime interaction and time-dependent changes were found for the outcome measures (p > 0.05). CONCLUSIONS: These findings established that, at 150 pps conventional TENS, threshold and tolerance values were consistently higher. These results are presented to inform future research regarding optimal conventional TENS parameters and to provide support for clinical applications.en_US
dc.item-language.isoengen_US
dc.publisherIos Pressen_US
dc.item-rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectTranscutaneous Electrical Nerve Stimulationen_US
dc.subjectFrequencyen_US
dc.subjectPressure Pain Thresholden_US
dc.subjectPressure Pain Toleranceen_US
dc.subjectAlgometeren_US
dc.titleEffects of different frequencies of conventional transcutaneous electrical nerve stimulation on pressure pain threshold and toleranceen_US
dc.item-typearticleen_US
dc.contributor.departmenten_US
dc.contributor.departmentTemp[Karakaya, Ilkim Citak; Karakaya, Mehmet Gurhan] Mugla Sitki Kocman Univ, Mugla Sch Hlth, Dept Physiotherapy & Rehabil, TR-48000 Mugla, Turkey -- [Ergun, Esra] Avicenna Hosp, Istanbul, Turkey -- [Elmali, Sedanur] Tokat State Hosp, Dept Physiotherapy & Rehabil, Tokat, Turkey -- [Firat, Tuzun] Hacettepe Univ, Fac Hlth Sci, Dept Physiotherapy & Rehabil, Ankara, Turkeyen_US
dc.identifier.doi10.3233/BMR-130436
dc.identifier.volume27en_US
dc.identifier.issue2en_US
dc.identifier.startpage197en_US
dc.identifier.endpage201en_US
dc.relation.journalJournal of Back and Musculoskeletal Rehabilitationen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster