Basit öğe kaydını göster

dc.contributor.authorHepbasli, Arif
dc.contributor.authorKecebas, Ali
dc.date.accessioned2020-11-20T16:19:41Z
dc.date.available2020-11-20T16:19:41Z
dc.date.issued2013
dc.identifier.issn0378-7788
dc.identifier.urihttps://doi.org/10.1016/j.enbuild.2013.02.019
dc.identifier.urihttps://hdl.handle.net/20.500.12809/3788
dc.descriptionWOS: 000320485500024en_US
dc.description.abstractThis paper comparatively evaluates exergy destructions of a geothermal district heating system (GDHS) using both conventional and advanced exergetic analysis methods to identify the potential for improvement and the interactions among the components. As a real case study, the Afyon GDHS in Afyonkarahisar, Turkey, is considered based on actual operational data. For the first time, advanced exergetic analysis is applied to the GDHSs, in which the exergy destruction rate within each component is split into unavoidable/avoidable and endogenous/exogenous parts. The results indicate that the interconnections among all the components are not very strong. Thus, one should focus on how to reduce the internal inefficiency (destruction) rates of the components. The highest priority for improvement in the advanced exergetic analysis is in the re-injection pump (PM-IX), while it is the heat exchanger (HEX-III) in the conventional analysis. In addition, there is a substantial influence on the overall system as the total avoidable exergy destruction rate of the heat exchanger (HEX-V) has the highest value. On the overall system basis, the value for the conventional exergetic efficiency is determined to be 29.29% while that for the modified exergetic efficiency is calculated to be 34.46% through improving the overall components. (c) 2013 Elsevier B.V. All rights reserved.en_US
dc.description.sponsorshipAfyon Geothermal Inc., Turkeyen_US
dc.description.sponsorshipThe authors would like to thank for the support provided by the Afyon Geothermal Inc., Turkey.en_US
dc.item-language.isoengen_US
dc.publisherElsevier Science Saen_US
dc.item-rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGeothermal Energyen_US
dc.subjectDistrict Heating Systemen_US
dc.subjectExergy Destructionen_US
dc.subjectConventional Exergetic Analysisen_US
dc.subjectAdvanced Exergetic Analysisen_US
dc.subjectBuildingsen_US
dc.titleA comparative study on conventional and advanced exergetic analyses of geothermal district heating systems based on actual operational dataen_US
dc.item-typearticleen_US
dc.contributor.departmenten_US
dc.contributor.departmentTemp[Hepbasli, Arif] Yasar Univ, Fac Engn, Dept Energy Syst Engn, TR-35100 Izmir, Turkey -- [Kecebas, Ali] Mugla Sitki Kocman Univ, Fac Technol, Dept Energy Syst Engn, Mugla, Turkeyen_US
dc.identifier.doi10.1016/j.enbuild.2013.02.019
dc.identifier.volume61en_US
dc.identifier.startpage193en_US
dc.identifier.endpage201en_US
dc.relation.journalEnergy and Buildingsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US