dc.description.abstract | We report on the determination of choline and acetylcholine via biocentrivoltammetry. This method combines centrifugation and voltammetry and is based on a carbon paste electrode modified with acetylcholinesterase and choline oxidase. The electrode was placed at the bottom of a biocentrivoltammetric cell. Acetylcholine and choline are accumulated on the enzyme electrode via centrifugative forces, upon which a direct voltammetric scan is applied. Reaction time, pH values, quantities of enzyme and centrifugation parameters were optimized. A linear response is obtained in the 0.07 to 10 mu M concentration range of acetylcholine, and a limit of detection as low as 0.5 mu M. The linear range is between 0.1 and 500 mu M for choline. The method was applied to the determination of acetylcholine and choline in spiked serum samples. | en_US |
dc.description.sponsorship | Technical and Scientific Council of Turkey (TUBITAK)Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [109T885]; Mugla Sitki Kocman University BAPMugla Sitki Kocman University [12/08] | en_US |
dc.description.sponsorship | The grant from The Technical and Scientific Council of Turkey (TUBITAK) Project no: 109T885 and Mugla Sitki Kocman University BAP project no 12/08 are gratefully acknowledged. | en_US |
dc.item-language.iso | eng | en_US |
dc.publisher | Springer Wien | en_US |
dc.item-rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Biocentri-Voltammetry | en_US |
dc.subject | Biosensor | en_US |
dc.subject | Acetylcholine | en_US |
dc.subject | Choline | en_US |
dc.title | Biocentri-voltammetric biosensor for acetylcholine and choline | en_US |
dc.item-type | article | en_US |
dc.contributor.department | MÜ | en_US |
dc.contributor.departmentTemp | [Cevik, Serdar; Anik, Ulku] Mugla Sitki Kocman Univ, Fac Sci, Dept Chem, Kotekli Mugla, Turkey -- [Timur, Suna] Ege Univ, Fac Sci, Dept Biochem, TR-35100 Izmir, Turkey | en_US |
dc.identifier.doi | 10.1007/s00604-012-0895-1 | |
dc.identifier.volume | 179 | en_US |
dc.identifier.issue | 3-4 | en_US |
dc.identifier.startpage | 299 | en_US |
dc.identifier.endpage | 305 | en_US |
dc.relation.journal | Microchimica Acta | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |