Basit öğe kaydını göster

dc.contributor.authorOsawa, Ikubun
dc.contributor.authorEsaka, Yuri
dc.contributor.authorKojima, Takashi
dc.contributor.authorSimsek, Cem
dc.contributor.authorKudo, Haruka
dc.contributor.authorDogru, Murat
dc.date.accessioned2020-11-20T14:39:38Z
dc.date.available2020-11-20T14:39:38Z
dc.date.issued2020
dc.identifier.issn2075-4418
dc.identifier.urihttps://doi.org/10.3390/diagnostics10040179
dc.identifier.urihttps://hdl.handle.net/20.500.12809/526
dc.descriptionSimsek, Cem/0000-0001-8003-745Xen_US
dc.descriptionWOS: 000534251000051en_US
dc.descriptionPubMed ID: 32218304en_US
dc.description.abstractStrip meniscometry tube (SMTube) is useful for assessing tear volume in dry eye disease. We performed an in vitro and a clinical study to examine whether the SMTube can also be used to evaluate tear quantity in lacrimal passage obstruction (LPO). In vitro experiments showed that the SMTube value and the amount of water absorption were significantly correlated (R-2 = 0.816, p = 0.0008), but the measured value peaked when 4 mu L was absorbed. In the clinical study, 12 eyes of 9 LPO patients and 17 eyes of 17 healthy control subjects were included. The patients' SMTube values were significantly higher than those of the control subjects (p < 0.05). The SMTube value significantly decreased after silicon tube intubation (p < 0.05). Tear meniscus height (TMH) and area (TMA), measured by anterior segment optical coherence tomography, exhibited a significant positive correlation with the SMTube value (TMH, p < 0.001, R-2 = 0.396; TMA, p < 0.001, R-2 = 0.366). Moreover, the SMTube value significantly correlated positively with the subjective symptom of epiphora (p = 0.012, R-2 = 0.255). Thus, SMTube was useful for evaluating the tear volume and therapeutic effects in patients with LPO.en_US
dc.item-language.isoengen_US
dc.publisherMdpien_US
dc.item-rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAnterior Segment Optical Coherence Tomographyen_US
dc.subjectEpiphoraen_US
dc.subjectLacrimal Drainage System Dysfunctionen_US
dc.subjectSilicon Tube Intubationen_US
dc.subjectStrip Meniscometry Tubeen_US
dc.subjectTear Meniscusen_US
dc.titleFeasibility of Strip Meniscometry for Tear Volume Evaluation in Lacrimal Passage Obstructionen_US
dc.item-typearticleen_US
dc.contributor.departmenten_US
dc.contributor.departmentTemp[Osawa, Ikubun; Esaka, Yuri; Kojima, Takashi] Japan Community Healthcare Org Chukyo Hosp, Dept Ophthalmol, Nagoya, Aichi 4578510, Japan -- [Kojima, Takashi; Simsek, Cem; Kudo, Haruka; Dogru, Murat] Keio Univ, Dept Ophthalmol, Sch Med, Tokyo 1608582, Japan -- [Simsek, Cem] Mugla Sitki Kocman Univ, Dept Ophthalmol, Sch Med, TR-48000 Mugla, Turkeyen_US
dc.identifier.doi10.3390/diagnostics10040179
dc.identifier.volume10en_US
dc.identifier.issue4en_US
dc.relation.journalDiagnosticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster