Basit öğe kaydını göster

dc.contributor.authorÖzkılıç, Yasin Onuralp
dc.contributor.authorÖzer, Zeybek
dc.contributor.authorTopkaya, Cem
dc.date.accessioned2021-12-23T11:56:49Z
dc.date.available2021-12-23T11:56:49Z
dc.date.issued2021en_US
dc.identifier.citation1.Özkılıç YO, Zeybek Ö, Topkaya C. Stability of laterally unsupported shear links in eccentrically braced frames. Earthquake Engineering & Structural Dynamics 2021. DOI: 10.1002/eqe.3593.en_US
dc.identifier.issn0098-8847
dc.identifier.issn1096-9845
dc.identifier.urihttps://doi.org/10.1002/eqe.3593
dc.identifier.urihttps://hdl.handle.net/20.500.12809/9715
dc.description.abstractI-shaped links in eccentrically braced frames (EBFs) are susceptible to lateral or lateral torsional buckling when subjected to cyclic link rotations. Lateral bracing should be provided at the ends of the I-shaped links in order to prevent these failures. Requirements for such braces are available in widely used design specifications such as the AISC Seismic Provisions for Structural Steel Buildings (AISC341-16) and EC8. These requirements limit the use of I-shaped links in bridge piers and elevator shafts. A combined experimental and numerical study was undertaken to investigate the behavior of laterally unsupported I-shaped links under cyclic loading. The experimental study consisted of testing of six nearly full-scale EBFs where the link length, link length ratio, and presence of lateral supports were considered as the prime variables. The test results demonstrated that short links with link length ratios less than 1.22 can experience inelastic link rotations greater than the codified limit of 0.08 rad even without lateral bracing. A numerical parametric study was conducted to develop more generalized design recommendations for laterally unsupported I-shaped shear links. Stability of one-story one-bay EBFs was studied using geometrically and materially nonlinear finite element analysis including imperfections. The numerical results showed that I-shaped links without lateral bracing can provide a stable response when the link length ratio is less than 1.15. In addition to this limit, the ratio of the elastic critical buckling capacity to the plastic shear capacity should be greater than 3.5 and 2.5 for links with and without axial force, respectively.en_US
dc.item-language.isoengen_US
dc.publisherWILEYen_US
dc.relation.isversionof10.1002/eqe.3593.en_US
dc.item-rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectEccentrically braced framesen_US
dc.subjectLateral bracingen_US
dc.subjectLateral torsional bucklingen_US
dc.subjectSeismic designen_US
dc.subjectShear linksen_US
dc.subjectSteelen_US
dc.titleStability of laterally unsupported shear links in eccentrically braced framesen_US
dc.item-typearticleen_US
dc.contributor.departmentMÜ, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.contributor.institutionauthorZeybek, Özer
dc.relation.journalEARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICSen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster