Basit öğe kaydını göster

dc.contributor.authorÖzkeskin, Mehmet
dc.contributor.authorÖzden, Fatih
dc.contributor.authorAr, Ege
dc.contributor.authorYüceyar, Nur
dc.date.accessioned2022-05-12T12:20:53Z
dc.date.available2022-05-12T12:20:53Z
dc.date.issued2022en_US
dc.identifier.citationMehmet Özkeskin, Fatih Özden, Ege Ar & Nur Yüceyar (2022): The reliability and validity of the 30-second chair stand test and modified four square step test in persons with multiple sclerosis, Physiotherapy Theory and Practice, DOI: 10.1080/09593985.2022.2070811en_US
dc.identifier.issn0959-3985 / 1532-5040
dc.identifier.urihttps://doi.org/10.1080/09593985.2022.2070811
dc.identifier.urihttps://hdl.handle.net/20.500.12809/9967
dc.description.abstractBackground The 30-second Chair Stand Test (30s-CST) and Modified Four Square Step Test (mFSST) are used to determine the functional status of individuals with multiple sclerosis (MS). No other studies have demonstrated the reliability and validity of the 30s-CST and mFSST. Purpose To identify the test-retest reliability, concurrent validity and the known-group validity of the 30s-CST and mFSST in persons with MS. Methods A total of 64 persons with MS were enrolled. 30s-CST, mFSST, Timed Up and Go Test (TUG) and Five Times Sit to Stand (FTST) tests were performed. 30s-CST and mFSST were conducted again one-hour later. Results The mean age of the persons with MS were 37.9 +/- 11.3 years. The test-retest reliability of the 30s-CST and mFSST were excellent (ICC30s-CST = 0.974, 95%CI: 0.95-0.98; ICCmFSST = 0.992, 95%CI: 0.98-0.99). The 30s-CST was strongly correlated with FTST and TUG (r(1) = -0.871, p(1) = 0.0001; r(2) = -0.741,p(2) = 0.0001). There was a strong relationship between mFSST with TUG and FTST (r(1) = 0.781,p(1) = 0.0001;r(2) = 0.788,p(2) = 0.0001). The SEM95 and MDC95 values of the 30s-CST and mFSST were 0.41/1.13 and 0.34/0.94, respectively. Besides, there were significant differences between the persons with or without fall history in 30s-CST (MD: 1.66, CI: 0.27 to 3.05, p = .019) and mFSST CST (MD:-2.70, CI: -4.73 to -0.67, p = .010) performances. Conclusion The 30s-CST and mFSST are both valid and reliable in mildly-disabled individuals with MS.en_US
dc.item-language.isoengen_US
dc.publisherTAYLOR & FRANCIS INCen_US
dc.relation.isversionof10.1080/09593985.2022.2070811en_US
dc.item-rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectChair stand testen_US
dc.subjectConcurrent validityen_US
dc.subjectKnown-group validityen_US
dc.subjectMinimal detectable changeen_US
dc.subjectReliabilityen_US
dc.titleThe reliability and validity of the 30-second chair stand test and modified four square step test in persons with multiple sclerosisen_US
dc.item-typearticleen_US
dc.contributor.departmentMÜ, Köyceğiz Sağlık Hizmetleri Meslek Yüksekokulu, Sağlık Bakım Hizmetleri Bölümüen_US
dc.contributor.authorID0000-0001-6593-3758en_US
dc.contributor.institutionauthorÖzden, Fatih
dc.relation.journalPHYSIOTHERAPY THEORY AND PRACTICEen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster