• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace@Muğla
  • Meslek Yüksekokulları
  • Muğla Meslek Yüksekokulu
  • Kimya ve Kimyasal İşleme Teknolojileri Bölümü Koleksiyonu
  • View Item
  •   DSpace@Muğla
  • Meslek Yüksekokulları
  • Muğla Meslek Yüksekokulu
  • Kimya ve Kimyasal İşleme Teknolojileri Bölümü Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Ultra-Trace Determination of Arsenic by Platinum-Coated Tungsten Coil Hydride Generation (HG) Atomic Absorption Spectrometry (AAS)

Thumbnail

View/Open

Tam metin / Full text (2.129Mb)

Date

2022

Author

Yıldız, Dilek
Atasoy, Muhammet
Demirak, Ahmet

Metadata

Show full item record

Citation

Dilek Yildiz, Muhammet Atasoy & Ahmet Demirak (2022): Ultra-Trace Determination of Arsenic by Platinum-Coated Tungsten Coil Hydride Generation (HG) Atomic Absorption Spectrometry (AAS), Analytical Letters, DOI: 10.1080/00032719.2022.2071913

Abstract

A simple, rapid, and sensitive method for the determination of ultra-trace arsenic (III) is reported based on in situ trapping and revolatilization on a platinum (Pt) coated tungsten (W) coil atom trap. First, the analyte species in vapor form were transported by a mixture of Ar and H-2 and trapped on the Pt-coated W-coil heated at 60 degrees C. Next, in the releasing step, the trap was resistively heated to 950 degrees C; the analyte species are revolatilized and transported to the quartz tube atomizer. The NaBH4 concentration, NaOH concentration, HCl concentration, trapping and releasing temperature, trapping time, and hydrogen and argon gas flow rates were optimized. Using these conditions, a limit of detection of 16 ng L-1 was obtained. The precision was evaluated by relative standard deviation corresponding to 4.8% at 1.0 mu g L-1 (n = 11). The surface of the W-coil trap was coated with Pt using electrolytic deposition. Scanning electron microscopy-energy dispersive X- ray (SEM-EDX) analyses were performed to control the surface morphology of the trap. The same trap may be used for at least 350 atomization cycles without losing sensitivity. The accuracy of the proposed method was evaluated by analyzing NIST CRM 1640a (Trace Elements in Natural Water), EnviroMAT (Drinking water), and CRM-023 (Sandy Loam 7) certified reference materials. The measurements of the certified reference materials were in good agreement with the certified values at the 95% confidence level. The developed method was applied to the determination of As in drinking water samples from Mugla province.

Source

ANALYTICAL LETTERS

URI

https://doi.org/10.1080/00032719.2022.2071913
https://hdl.handle.net/20.500.12809/9983

Collections

  • Kimya ve Kimyasal İşleme Teknolojileri Bölümü Koleksiyonu [65]
  • Scopus İndeksli Yayınlar Koleksiyonu [6219]
  • WoS İndeksli Yayınlar Koleksiyonu [6466]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Muğla

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Guide|| Instruction || Library || Muğla Sıtkı Koçman University || OAI-PMH ||

Muğla Sıtkı Koçman University, Muğla, Turkey
If you find any errors in content, please contact:

Creative Commons License
Muğla Sıtkı Koçman University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.