• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Muğla
  • Fakülteler
  • Tıp Fakültesi
  • Cerrahi Tıp Bilimleri Bölümü Koleksiyonu
  • Öğe Göster
  •   DSpace@Muğla
  • Fakülteler
  • Tıp Fakültesi
  • Cerrahi Tıp Bilimleri Bölümü Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Comparison of the results of four different refraction measurement devices in children with retinoscopy

Thumbnail

Göster/Aç

Tam metin / Article (1.140Mb)

Tarih

2022

Yazar

Şimşek, Merve
Oral,Yeşim
Eroğul, Özgür
Sabaner, Mehmet Cem
Şimşek, Hüseyin Cem
Yörükoğlu, Seray

Üst veri

Tüm öğe kaydını göster

Künye

Simsek M, Oral Y, Erogul O, Sabaner MC, Simsek C, Yorukoglu S. Comparison of the results of four different refraction measurement devices in children with retinoscopy. Rom J Ophthalmol. 2022 Oct-Dec;66(4):337-343. doi: 10.22336/rjo.2022.60. PMID: 36589324; PMCID: PMC9773113.

Özet

Purpose: The purpose of this study was to compare the results of 4 different autorefractometer devices with the results of retinoscopy in children. Methods: A total of 120 eyes of 60 patients aged between 6 and 18, who applied to Afyonkarahisar Health Sciences University unit of Pediatric Ophthalmology, were included in the study. Refraction with Plusoptix A09 (photoscreener) without cycloplegia was the first to be measured. Spherical and cylindrical values were recorded. Then, half an hour after the patients were instilled 2 drops of cyclopentolate with an interval of 5 minutes, dilated retinoscopy was performed, and spherical and cylindrical values were recorded. Autorefractometer measurements with cycloplegia were performed with Canon RK-F1 autorefractometer, Nidek Tonoref III and Retinomax K-Plus 3, and spherical and cylindrical values were recorded. Results: The mean age of the patients was 11.02 ± 2.1. The mean spherical equivalents were Canon RKF1 autorefractometer +0.045 ± 2.49, Nidek TonoRef III +0.023 ± 2.48, Retinomax K-Plus 3 +0.078 ± 1.42, Plusoptix A09 -0.119 ± 2.20, retinoscopy +0.124 ± 2.65. Moreover, the mean cylindrical values were Canon RK-F1 autorefractometer -0.893 ± 0.69, Nidek TonoRef III -0.927 ± 0.72, Retinomax K-Plus 3 -0.888 ± 0.73, Plusoptix A09 -0.883 ± 0.719, retinoscopy -0.923 ± 0.71. The statistical values compared with retinoscopy; Canon RKF1 spherical equivalent (p=0.376), cylindrical (p=0.515), Nidek TonoRef III spherical equivalent (p=0.485), cylindrical (p=0.198), Retinomax K-Plus 3 spherical equivalent (p=0.141), cylindrical (p=0.058), Plusoptix A09 spherical equivalent (p=0.085) and cylindrical (p=0.086) values were not different. Conclusions: In spherical and cylindrical refractive error detection, all 4 devices showed reasonable and consistent results compared to retinoscopy.

Kaynak

Romanian Journal of Ophthalmology

Cilt

66

Sayı

4

Bağlantı

https://hdl.handle.net/20.500.12809/10480

Koleksiyonlar

  • Cerrahi Tıp Bilimleri Bölümü Koleksiyonu [543]
  • PubMed İndeksli Yayınlar Koleksiyonu [2082]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.