• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Muğla
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • TR-Dizin İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace@Muğla
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • TR-Dizin İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Statistical analysis of blood cells and blood proteins behaviours contacted with PMEA-coated and uncoated oxygenators

Tarih

2012

Yazar

Ayhan, Fatma
Kocakulak, Mustafa
Akpolat, Oğuz
Ayhan, Hakan

Üst veri

Tüm öğe kaydını göster

Özet

Polimetoksietilen akrilat (PMEA) kaplı ve kapsız oyuk fiberlerin kan uyumluluğu multivariat istatistiksel yöntemler kullanılarak incelenmiştir. Hastalar iki gruba ayrılmıştır: biri PMEA kaplı diğeri de kapsız oksijeneratör fiberlerleri kullanan hastalar. Her iki grup da toplam bilirubin, direkt bilirubin, eritrosit, albumin, fibrinojen, lökosit ve toplam protein analiz sonuçları ile değerlendirilmiştir. Karşılaştırma için üç düzey alınmıştır: taban seviyesi (T1), protamin enjeksiyonu sonrası (T4) ve yoğun bakım (T5). Düzeyler arasında belirgin farklılıklar gözlenmemiştir. Ek olarak ölçümler yaşa göre de karşılaştırılmıştır. Hastalar dört farklı yaş grubuna ayrılmıştır ve yoğun bakım fibrinojen değeri ve taban seviyesi protrombin zamanı (Pt) değeri hariç yaş grupları arasında bir fark bulunmamıştır. Sonra ölçümlerin önemli ilişki değerini bulmak için deneme yapıldı. Önemli bir tane bulunduktan sonra regrasyon modelinde, bir ölçüm bağımlı değişken olarak ve bağımlı değişkenle çok iyi bağlantı kuran ölçümler de bağımsız değişkenler olarak alınmıştır. Analizde kurulan modellerin hepsinin r2, p ve F değerleri önemlidir. Bazı regrasyon modellerinde sadece etkileşim etkisi değişkenlerle birlikte görülmüştür ki bunun anlamı, Kaplanmış cardiopulmoner by pass filtreleri, kaplanmamışlar ile karşılaştırıldığında PMEA kaplılar protein adsorpsiyonu için daha hidrofilik yüzeyler oluşturmuştur.
 
The blood compatibility of the polymethoxyethyle acrylate (PMEA) coated and uncoated hollow fibers were investigated using multivariate statistical methods. The patients were divided into two groups where one is PMEA-coated fibers used patients and the other is uncoated oxygenator fibers used patients. The two groups were evaluated by total bilirubin, direct bilirubin, erythrocyte, albumin, fibrinogen, leukocyte, and total protein analysis results. Three evaluations were taken for comparison: baseline (T1), after protamine injection (T4) and intensive care (T5). There are no significant differences in the comparison. Additionally, the measurements were also compared by age. The patients were divided to four different age groups and no differences were found between the age groups except intensive care fibrinogen value and baseline protrombine time (Pt) Value. Then attempt were made to look for the significant correlation value of the measurements. After significant one was found, one measurement value was taken as dependent variable and the measurements, which are highly correlated with dependent variable as independent variables in the regression model. All of the models established that the analysis were significant with both squared r, p and F values. In some regression models, only interaction effect was seen with the variables, which means that PMEA-coating created more hydrophilic surfaces for protein adsorption when compared with uncoated Cardiopulmonary by pass filters.
 

Kaynak

Hacettepe Journal of Biology and Chemistry

Cilt

40

Sayı

4

Bağlantı

https://app.trdizin.gov.tr//makale/TVRNNU1qY3lNZz09
https://hdl.handle.net/20.500.12809/8433

Koleksiyonlar

  • TR-Dizin İndeksli Yayınlar Koleksiyonu [3005]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Muğla

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber|| Yönerge || Kütüphane || Muğla Sıtkı Koçman Üniversitesi || OAI-PMH ||

Muğla Sıtkı Koçman Üniversitesi, Muğla, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Muğla Sıtkı Koçman Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Muğla:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.