dc.identifier.citationKarababa H, Atasoy M, Yildiz D, Kula İ, Tuzen M. Development of a Sensitive Method for Cadmium Determination in Fish Tissue and Drinking Water Samples by FAAS Using SQT In Situ Atom Trapping. ACS Omega. 2023 Feb 13;8(7):7063-7069. doi: 10.1021/acsomega.2c07926. PMID: 36844526; PMCID: PMC9947951.en_US
dc.identifier.urihttps://doi.org/10.1021/acsomega.2c07926
dc.identifier.urihttps://hdl.handle.net/20.500.12809/10566
dc.description.abstractA sensitive and robust trap method was developed for the determination of cadmium (Cd) by using a slotted quartz tube. Using this method at a sample suction rate of 7.4 mL/min for 4.0 min collection, a 1467-fold increase in sensitivity was obtained compared to the flame atomic absorption spectrometry method. Under the optimized conditions, a limit of detection of 0.075 ng mL-1 was obtained for the trap method. The interference effects of hydride-forming elements, transition metals, and some anions on the Cd signal were investigated. The developed method was evaluated by analyzing "Sewage Sludge-industrial origin (BCR no: 146R)", "NIST SRM 1640a Trace elements in natural water", and "DOLT: 5 Dogfish Liver". There was a good agreement between the certified and found values at the 95% confidence level. This method was applied successfully for the determination of Cd in drinking water and some fish tissue samples (liver, muscle, and gill) obtained from Muğla province.en_US
dc.item-language.isoengen_US
dc.publisherACSen_US
dc.relation.isversionof10.1021/acsomega.2c07926en_US
dc.item-rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectRobust trap methoden_US
dc.titleDevelopment of a Sensitive Method for Cadmium Determination in Fish Tissue and Drinking Water Samples by FAAS Using SQT In Situ Atom Trappingen_US
dc.item-typearticleen_US
dc.contributor.departmentMÜ, Fen Fakültesi, Kimya Bölümüen_US
dc.contributor.authorID0000-0003-4312-1876en_US
dc.contributor.authorID0000-0001-9325-7187en_US
dc.contributor.institutionauthorKarababa, Hüseyin
dc.contributor.institutionauthorAtasoy, Muhammet
dc.contributor.institutionauthorYıldız, Dilek
dc.contributor.institutionauthorKula, İbrahim
dc.identifier.volume8en_US
dc.identifier.issue7en_US
dc.identifier.startpage7063en_US
dc.identifier.endpage7069en_US
dc.relation.journalACS Omegaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster